Evaluation of the Diagnostic Accuracy of Different Imaging Modalities in Patients with Pathologic Nipple Discharge.
Riku Togawa, Dina Batarseh, Helena Dahm, Thomas M Deutsch, André Hennigs, Andrea Lemke, André Pfob, Walid Shaalan,
Breast Unit, Department of Obstetrics and Gynecology, Heidelberg University Hospital, Im Neuenheimer Feld 440, 69120 Heidelberg, Germany. · Department of Diagnostic and Interventional Radiology, Heidelberg University Hospital, Im Neuenheimer Feld 440, 69120 Heidelberg, Germany.
Key points
From the paper's conclusion- Background/Objectives: To evaluate the diagnostic accuracy of different imaging modalities in patients with pathologic nipple discharge.
Abstract
Background/Objectives: To evaluate the diagnostic accuracy of different imaging modalities in patients with pathologic nipple discharge. Methods: This is a single-centre retrospective analysis of patients with pathologic nipple discharge. All performed imaging modalities were reviewed for their sensitivity and specificity in correctly diagnosing malignancy, as well as lesions with uncertain malignant potential (B3). Results: Of 388 patients, pathology or follow-up confirmed 41 cases of malignancy (15 breast cancer, 26 ductal carcinoma in situ (DCIS)), 151 cases of B3 lesions, and 196 benign cases. The combination of ultrasound and mammography/tomosynthesis achieved a sensitivity of 82.5% (95% CI 68.1-91.3) and a specificity of 83.5% (77.4-88.2) for the detection of malignancy. For the classification of B3 lesions as suspicious (BI-RADS 4/5), the sensitivity and specificity were 33.8% (26.7-41.7) and 83.5% (77.4-88.2), respectively. Ductography demonstrated a sensitivity of 89.3% (72.8-96.3) and a specificity of 13.3% (8.2-20.8) for malignancy, while MRI showed a sensitivity of 71.4% (45.4-88.3) and a specificity of 90.0% (76.9-96.0). In classifying B3 lesions as suspicious, ductography reached a sensitivity of 94.8% (89.7-97.5) and a specificity of 13.3% (8.2-20.8), compared to 75.9% (57.9-87.8) and 90.0% (76.9-96.0), respectively, for MRI. Conclusions: While the combination of ultrasound and mammography/tomosynthesis correctly classified 82.5% of breast malignancies associated with pathologic nipple discharge as suspicious, their sensitivity for classifying B3 lesions as suspicious was only moderate (33.8%). In patients with negative or inconclusive conventional imaging but persistent clinical suspicion, MRI may be considered as an additional diagnostic tool, whereas ductography, given its low specificity, is of limited value for assessing lesion dignity and may primarily serve to localize the affected duct prior to surgery. Further research is needed to determine which diagnostic modality provides the greatest benefit in specific cases.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Tumor Involvement of the Nipple at Preoperative Contrast-enhanced Mammography: A Multicenter Diagnostic Accuracy StudyRadiology · 2025
- Diagnostic performance of S-detect artificial intelligence compared with conventional breast ultrasound for lesion characterization: a prospective lesion-based studyEgyptian Journal of Radiology and Nuclear Medicine · 2026
- Diagnostic performance of machine learning algorithms in breast ultrasound: A systematic review and meta-analysisPolish Journal of Medical Physics and Engineering · 2026
- Comparative evaluation of ResNet-Based AI models for breast cancer detection in digital mammography and digital breast tomosynthesis.Frontiers in systems biology · 2026
- Mammography and Ultrasonography for Symptomatic Male Breast Lesions: A PRISMA-DTA Systematic Review and Meta-analysis.Academic radiology · 2026
- Feasibility of Auditing Preoperative Breast MRI for Extent-of-Disease Evaluation Using the BI-RADS v2025 ManualRadiology · 2025