Factors Associated with the Accuracy of Sonographic Fetal Weight Estimation: A Study of 1262 Vietnamese Pregnancies.
Ngoc Diem Doan Phan, Quang Chi Nguyen, Trang Thi Thu Nguyen, Xuan Thi Huong Nguyen, Nhung Huynh Ho, Quang Sy Nguyen, Thuy Thi Chau, Duong Huu Quach,
Department of Obstetrics and Gynecology, Vinmec Central Park International Hospital, Vinmec International Hospital, Ho Chi Minh City 70000, Vietnam. · School of Medicine, University of Medicine and Pharmacy at Ho Chi Minh City, Ho Chi Minh City 70000, Vietnam.
Key points
From the paper's conclusion- We examined maternal, fetal and sonographic factors associated with EFW error using the Hadlock II, Hadlock III and Shinozuka formulas.
Abstract
Background/Objectives: Sonographic estimated fetal weight (EFW) guides many obstetric decisions. We examined maternal, fetal and sonographic factors associated with EFW error using the Hadlock II, Hadlock III and Shinozuka formulas. Methods: This is a retrospective cross-sectional study of 1262 singleton pregnancies at 30-41 weeks scanned within 3 days before delivery. Accuracy was assessed by mean percentage error (MPE), mean absolute percentage error (MAPE), successful estimation rate (SER; error ≤ 10%), Bland-Altman analysis with regression-based limits of agreement and Deming regression. Formulas were compared with paired tests. Each factor's contribution was measured as the decrease in Nagelkerke R2 (ΔR2) in multivariable logistic regression; factor × formula interactions were tested with generalised estimating equations (GEE). Results: MAPE was 5.44%, 5.64% and 5.75% and SER 86.2%, 84.2% and 84.5% for Hadlock II, Hadlock III and Shinozuka, respectively; differences between formulas were small (ΔMAPE ≤ 0.31 percentage points). Against birth weight, all three overestimated small and underestimated large fetuses (Deming slopes 0.79-0.85). Birth weight was the strongest correlate of SER (decrease in Nagelkerke R2, 0.052-0.129) and, in the main analysis, the only factor whose effect differed between formulas (p < 0.001); other factors reduced Nagelkerke R2 by <0.02. Sensitivity was 42-66% for the 89 neonates < 2500 g and 18-38% for the 39 neonates ≥ 4000 g; positive predictive values were 78-82% and 88-100%, respectively, the latter based on 8-16 estimates (lower 95% confidence limits, 47-74%). Conclusions: EFW error was mainly associated with fetal size; this pattern, partly due to regression towards the mean, cannot be used as a bedside correction. Other characteristics showed little additional association with accuracy. The differences between the formulas were small, their clinical relevance is unclear, and none is recommended over the others. An EFW of 2500-2999 g does not exclude low birth weight, and an EFW of 3500-3999 g does not exclude a neonate of ≥4000 g.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Accuracy of fetal weight estimation at term: comparison of conventional and soft tissue-based ultrasound methods.European journal of obstetrics, gynecology, and reproductive biology · 2026
- Association of sonographic estimated fetal weight with primary cesarean delivery after adjustment for neonatal birthweight in term nulliparous pregnancies.Frontiers in medicine · 2026
- Selection of standards for estimated fetal weight percentiles.Pregnancy (Hoboken, N.J.) · 2026
- Development of Novel Prenatal Prediction Models for Birth-Weight Estimation in Low-Risk Third-Trimester Pregnancies.Biomedicines · 2026
- Comparison of ultrasound accuracy versus clinical fetal weight estimation - a retrospective cross-sectional study.Ginekologia polska · 2026
- Comparison of Fetal Growth Standards for Predicting Small-for-Gestational-Age Infants and Adverse Pregnancy Outcomes.Journal of ultrasound in medicine : official journal of the American Institute of Ultrasound in Medicine · 2026