Diagnostics (Basel, Switzerland)

Dynamic Xenon-Enhanced Spectral CT Imaging to Evaluate Regional Lung Function in an In Vivo Rabbit Model.

Emma Verelst, Sam Bayat, Sylvia Verbanck, Gert Van Gompel, Johan de Mey, Nico Buls

Department of Radiology, Research Centre For Digital Medicine (REDM), Universitair Ziekenhuis Brussel (UZ Brussel), Vrije Universiteit Brussel (VUB), Laarbeeklaan 101, 1090 Brussels, Belgium. · Inserm UA07 STROBE Laboratory, Université Grenoble Alpes, Rue De La Piscine 2280, 38400 Grenobles, France.

Preclinical

Key points

From the paper's conclusion
  • Conclusions: Dynamic Xe-DECT imaging enabled spatial and quantitative assessments of specific ventilation and tissue densities in an in vivo rabbit model.

Abstract

Background/Objectives: Pulmonary diseases exhibit spatially heterogeneous functional and structural abnormalities that are inadequately represented by conventional lung function testing. This pilot study investigates dynamic xenon-enhanced dual-energy CT (Xe-DECT) for a multiparametric assessment of lung ventilation and tissue. Methods: Four mechanically ventilated rabbits were scanned during washout of 70% xenon in oxygen using multibreath imaging with a clinical DECT both before (baseline) and after methacholine administration (post-MCh). Tracheal Xe concentration (CXe) and flow were monitored using mass spectrometry and pneumotachometry to estimate specific ventilation (sV˙ms) and end-expiratory lung volume (EELVms). DECT-derived xenon concentration and tissue density images (mg/mL) were obtained by material decomposition, yielding sV˙DECT and EELVDECT, respectively. Agreement with mass spectrometry and differences between baseline and post-MCh were assessed. Results: The baseline sV˙DECT and EELVDECT agreed with the mass spectrometry, with mean differences of 0.6 min-1 [-0.2 min-1, 1.4 min-1] and 0.6 mL [-6.7 mL, 7.9 mL], respectively. Following MCh administration, the mean differences increased to -2.9 min-1 [-4.1 min-1, -1.6 min-1] for sV˙ and 1.3 mL [-15.3 mL, 12.8 mL] for EELV. Post-MCh, sV˙DECT decreased from 8.6 ± 1.6 min-1 to 3.7 ± 0.9 min-1 (p = 0.034) and EELVDECT from 29.3 ± 1.0 mL to 27.0 ± 1.3 mL (p = 0.036), whereas sV˙ms (p = 0.308) and EELVms (p = 0.653) showed no substantial changes. Regional analysis revealed that sV˙DECT in well-ventilated regions matched tracheal sV˙ms. Conclusions: Dynamic Xe-DECT imaging enabled spatial and quantitative assessments of specific ventilation and tissue densities in an in vivo rabbit model. This technique allowed detection of focal alterations that remained undetected by tracheal measurements.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers