Diagnostics (Basel, Switzerland)

Development and External Validation of Machine Learning Models for Ionized Calcium Estimation in Hypoalbuminemia.

Levent Deniz, Tugay Solar, Ipek Deveci Kocakoc, Berrin Bercik Inal, Okan Dikker, Cengiz Aydin

Department of Medical Biochemistry, University of Health Sciences, Istanbul Training and Research Hospital, 34098 Istanbul, Türkiye. · Department of Econometrics, Faculty of Economics and Administrative Sciences, Dokuz Eylul University, 35340 Izmir, Türkiye.

Computational · n=14,745

Key points

From the paper's conclusion
  • Background/Objectives: This study aimed to develop and evaluate machine learning models for predicting ionized calcium levels in patients with hypoalbuminemia, compare their performance with classical correction formulas and unadjusted total calcium levels, and assess their transportability through external validation.

Abstract

Background/Objectives: This study aimed to develop and evaluate machine learning models for predicting ionized calcium levels in patients with hypoalbuminemia, compare their performance with classical correction formulas and unadjusted total calcium levels, and assess their transportability through external validation. Methods: In a retrospective development cohort of 14,745 adults with hypoalbuminemia, XGBoost and ordinary least squares (OLS) models used total calcium, albumin, total protein, and eGFR and were evaluated with nested cross-validation. Frozen models were then applied without recalibration to an independent external cohort of 2751 patients using the same analyzer platforms. Results: Development XGBoost performance was R2 = 0.500 and AUC-ROC = 0.798 (95% CI 0.788-0.807), with 98.5% sensitivity and 26.0% specificity. External R2 was 0.397 for XGBoost and 0.363 for OLS. External AUC-ROC was 0.818 (95% CI 0.791-0.845) for XGBoost, 0.823 (0.797-0.850) for OLS, and 0.819 (0.791-0.845) for total calcium. Threshold-matched and exploratory decision-curve analyses showed no clear incremental XGBoost advantage over total calcium. Conclusions: Machine learning models provided useful continuous ionized-calcium estimates and high sensitivity for hypocalcemia detection, although specificity was low. In independent external validation, hypocalcemia discrimination was comparable to unadjusted total calcium. The models should be considered complementary rather than substitutes for measured ionized calcium, and further multicenter and prospective evaluation is warranted.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers