Panel-Specific Optimization and Benchmarking of Copy-Number Callers for ERBB2 Amplification Detection Using the Nanodigmbio NanOnco Plus Panel v3.0.

Alexey Aleksandrovich Traspov, Peter Alekseevich Shatalov, Maria Alexandrovna Revkova, Polina Vladimirovna Mishakova, Elena Alekseevna Kirillova, Maria Pavlovna Raygorodskaya, Daria Valerievna Bagdasarova, Irina Alexeevna Leukhina,

National Medical Research Radiological Centre of the Ministry of Health of the Russian Federation, 249036 Obninsk, Russia.

Computational · n=126

Key points

From the paper's conclusion
  • We evaluated panel-specific ERBB2 analysis configurations against a binary FISH reference, with emphasis on the distinction between development-set performance and internal validation.

Abstract

Background/Objectives: ERBB2 amplification is a clinically relevant breast-cancer biomarker, but CNV detection from targeted sequencing depends on assay design, normalization, tumor fraction, and decision rules. We evaluated panel-specific ERBB2 analysis configurations against a binary FISH reference, with emphasis on the distinction between development-set performance and internal validation. Methods: We retrospectively evaluated 126 FFPE breast-tumor specimens (59 FISH-positive and 67 FISH-negative; 123 recorded patient identifiers) sequenced using NanOnco Plus Panel v3.0 on DNBSEQ-G400. Seven tumor-only, panel-compatible CNV caller configurations were compared; no matched normal tissue was available, although panel-matched normal reference pools were used where required by a caller. PureCN was run as a standalone tumor-only workflow, and CNVkit was run independently. Original fixed-rule results were calculated on the development cohort. An additional common 5-fold, 20-repeat patient-grouped cross-validation procedure selected decision rules using training data only, maximizing sensitivity subject to training specificity ≥90%. Upstream caller outputs were held fixed. Technical no-calls were retained. Results: On the development cohort, the fixed CNVkit median-bin log2 rule yielded 76.3% sensitivity (Wilson 95% CI, 64.0-85.3%) and 91.0% specificity (81.8-95.8%), with F1 81.8% and κ = 0.679. Native standalone PureCN yielded 16.9% sensitivity and 95.5% specificity at absCN ≥ 14; PURPLE had three numerical no-calls. Under the common patient-grouped decision-calibration procedure, CNVkit yielded 67.8% sensitivity and 91.0% specificity, whereas native PureCN yielded 19.3% sensitivity and 91.2% specificity. Exploratory computational purity subgroups and descriptive profiles across 554 genes illustrated heterogeneity of the measured DNA copy-number signal; independent pathology cellularity was unavailable, while quantitative FISH fields were recovered only for 45 of 126 specimens and were not used to define the full-cohort benchmark. Conclusions: The results support assay-specific development of ERBB2 decision rules but do not establish an intrinsic ranking of CNV software or clinical validation of other panel genes. The original full-cohort metrics are development-set estimates, and the additional cross-validation is conditional on previously generated caller outputs. External validation with independently assessed tumor content and complete clinical HER2 adjudication remains necessary.

Read the paper