Diagnostics (Basel, Switzerland)

Machine Learning Detection of Peritoneal Entry from Vibroacoustic Signals During Veress Needle Insertion.

Moritz Spiller, Mohammad Rezapourian, Axel Boese, Alfredo Illanes, Thomas Neumuth, Nazila Esmaeili

Innovation Center Computer Assisted Surgery (ICCAS), University of Leipzig, Semmelweissstr. 14, 04103 Leipzig, Germany. · Department of Neuroradiology, Medical Faculty, Otto-von-Guericke University, Leipziger Str. 44, 39120 Magdeburg, Germany.

Computational

Key points

From the paper's conclusion
  • Conclusions: These results establish the feasibility of automatically detecting peritoneal entry across a phantom-to-porcine domain shift and extend the descriptive cadaveric characterisation of the puncture signature toward the automated machine learning-based detection of peritoneal entry in laparoscopic access with a Veress needle.

Abstract

Background/Objectives: Establishing access is a hazardous step of laparoscopic surgery, and the widely used Veress needle offers only subjective tactile and auditory cues for peritoneal entry. Proximal vibroacoustic (VA) sensing captures needle-tissue interaction non-invasively and is known to contain a characteristic peritoneal puncture signature, which could help surgeons to precisely identify peritoneal entry. However, the VA signature has been evaluated only by retrospective, video-anchored and manual signal analysis. We investigate whether peritoneal entry can instead be detected automatically. Methods: Cavity entry is framed as a binary classification of VA signal segments, and four model families are benchmarked under a single unified protocol: a one-dimensional convolutional neural network (1D CNN), a multilayer perceptron, a bidirectional long short-term memory network (LSTM), and a support vector machine (SVM) with a radial basis function kernel. All models were trained, selected, and threshold-tuned on a synthetic abdominal phantom (996 segments) and tested once on an independent porcine cadaver dataset (154 cavity, 462 non-cavity signals) so that every test result measures generalisation across a phantom-to-porcine domain shift. Results: The 1D CNN performed the best (accuracy 0.869, AUROC 0.904, macro F1 0.833, cavity recall 0.818), closely followed by the SVM (AUROC 0.900, AUPRC 0.878). Conclusions: These results establish the feasibility of automatically detecting peritoneal entry across a phantom-to-porcine domain shift and extend the descriptive cadaveric characterisation of the puncture signature toward the automated machine learning-based detection of peritoneal entry in laparoscopic access with a Veress needle.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers