Diagnostic Performance of 99mTc-MAG3 Renal Scintigraphy for Acute Tubular Necrosis and Acute Rejection in Kidney Transplant Recipients with Suspected Graft Dysfunction During the First 90 Days: A Single-Center, Biopsy-Referenced Retrospective Study.
Ashraf Imam, Suha Shabaneh, Riham Imam, Michael Rivin, Ahmad Salhab, Itamar Tamir, Keren Tzukert, Roy Abel,
Organ Transplantation Unit, Department of Surgery, Hadassah-Hebrew University of Jerusalem, Jerusalem 91120, Israel. · Department of Radiology, Hadassah-Hebrew University of Jerusalem, Jerusalem 91120, Israel.
Key points
From the paper's conclusion- We assessed 99mTc-MAG3 scintigraphy against biopsy.
Abstract
Background: Acute tubular necrosis (ATN) and acute rejection are the principal parenchymal causes of early kidney allograft dysfunction, and biopsy is the reference standard for distinguishing them. We assessed 99mTc-MAG3 scintigraphy against biopsy. Methods: Single-center retrospective study of transplants (2016 to 2025) scanned within 90 days for suspected graft dysfunction: 42 transplants in 41 recipients, 10% of 420 screened. Accuracy was calculated only in the 25 with a paired biopsy, with exact 95% confidence intervals (CIs). Because biopsy was performed on clinical indication and not in all patients, verification bias was quantified by Begg-Greenes correction and extreme-case bounds. Results: Scintigraphy was performed a median of 8 days after transplantation; 69% had delayed graft function. Scans were read as ATN in 31 (74%), normal in seven (17%), rejection in three (7%) and obstruction in one; biopsy showed ATN in 15, rejection in six and normal histology in four. For ATN, sensitivity was 14/15 (93.3%; CI 68.1 to 99.8), specificity 7/10 (70.0%; 34.8 to 93.3) and positive predictive value 14/17 (82.4%; 56.6 to 96.2). For rejection, sensitivity was 3/6 (50.0%; 11.8 to 88.2) and specificity 19/19 (100%; 82.4 to 100), the predictive value of three positive scans being uninformative (CI 29.2 to 100). Correcting for verification placed ATN specificity between 29.2% and 76.9% and rejection sensitivity between 13.0% and 50.0%. Conclusions: Scintigraphy rarely missed biopsy-proven ATN but was not specific and identified only half of the rejection episodes. These estimates rest on small numbers in a clinically selected population; biopsy remains necessary whenever rejection is suspected, and they do not apply to routine or protocol scintigraphy.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- A multicenter prospective validation cohort does not support the use of kidney/psoas [18F]FDG uptake in the diagnosis of kidney allograft subclinical rejection.PloS one · 2026
- One-stop early noninvasive evaluation of renal allograft rejection and fibrosis: microstructural mapping via time-dependent diffusion MRIEBioMedicine · 2025
- Practical Recoverability and Numerical Identifiability of Kinetic Rate Constants from Noisy Time-Activity Curves in a Patient-Derived Renogram Model.Molecular imaging · 2026
- Repeated histological diagnoses and kidney graft failure: an observational cohort studymedRxiv · 2026
- Impact of ROI delineation methods on the repeatability of quantitative indices in 99mTc-MAG3 diuretic renography.The quarterly journal of nuclear medicine and molecular imaging : official publication of the Italian Association of Nuclear Medicine (AIMN) [and] the International Association of Radiopharmacology (IAR), [and] Section of the Society of... · 2026
- First Order Associations Between Banff Acute Lesions in Kidney Allograft Biopsies and a Urinary Cell Three-Gene Diagnostic Signature.bioRxiv : the preprint server for biology · 2026