A Clinician-Configurable FAHP-Based Ensemble Framework for Multi-Label Chest X-Ray Classification.
Hui-Chu Chiu, Yu-Hsiang Tsai, Cheng-Hsuan Juan, Chia-Ching Chang, Ya-Hui Li, Deng-Yiu Chiu, Chun-Jung Juan
Ph.D. Program of Management, Chung-Hua University, Hsinchu 300, Taiwan. · Department of Medical Imaging, China Medical University Hsinchu Hospital, Hsinchu 302, Taiwan.
Key points
From the paper's conclusion- This framework provides an aggregation-level transparent approach for incorporating configurable diagnostic priorities into multi-label CXR classification.
Abstract
Background/Objectives: Deep learning-based chest X-ray (CXR) analysis has shown strong diagnostic performance; however, conventional ensemble methods typically rely on equal-weight aggregation and do not account for disease-specific model behavior or clinician-defined priorities. Methods: We developed a clinician-configurable ensemble framework based on the fuzzy analytic hierarchy process (FAHP) for multi-label CXR classification. The proposed method employs a two-stage design consisting of disease-specific model weighting using multi-criteria decision analysis and utility-guided seed aggregation based on ΔNet Benefit (ΔNB). Five base architectures, including Vision Transformer (ViT), SwinV2 Transformer, DenseNet121, DenseNet121 + ViT and DenseNet121 + SwinV2, were trained on the National Institutes of Health (NIH) ChestX-ray14 dataset using 10 random seeds. Performance was evaluated on a held-out test set using area under the receiver operating characteristic curve (AUROC), area under the precision-recall curve (AUPRC), balanced accuracy, and F1 score and compared with single-model baselines, Hard Voting, and Soft Voting. Results: In the seed-level analyses, Soft Voting achieved the highest overall discrimination performance (AUROC, 0.851 ± 0.001; AUPRC, 0.293 ± 0.003), whereas seed-level FAHP showed comparable performance (AUROC, 0.850 ± 0.001; AUPRC, 0.287 ± 0.004). In the final-level analyses, the sensitivity-priority FAHP-ΔNB configuration achieved a macro-averaged AUROC of 0.855 and an AUPRC of 0.299. Hard Voting demonstrated inferior performance, particularly for AUPRC. Per-disease analysis revealed heterogeneous results, with FAHP showing favorable performance in selected conditions, including Effusion, Emphysema, Mass, Nodule, and Pleural Thickening, while Soft Voting remained superior in others. Statistical analysis confirmed that differences between FAHP and Soft Voting were generally modest and disease-dependent. Conclusions: The proposed FAHP-based ensemble maintains performance comparable to strong equal-weight baselines while enabling clinician-configurable, disease-specific model weighting and utility-guided aggregation. This framework provides an aggregation-level transparent approach for incorporating configurable diagnostic priorities into multi-label CXR classification.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Is a CNN-Transformer Ensemble Worth It When a Chest X-Ray Foundation Model Is Available?arXiv · 2026
- CXR-CMFA: A Cross-Modal Feature Aggregation Network for Chest X-Ray Pathology ClassificationarXiv · 2026
- Hierarchical attention and systematic fusion: optimizing multimodal learning for interpretable thoracic disease classificationMachine Learning for Computational Science and Engineering · 2026
- An intelligent decision support framework for automated pneumonia classification from chest X-ray images using hybrid vision transformers and CNNsIntelligence-Based Medicine · 2026
- A monotonic multi-expert Vision Transformer for clinically reliable chest X-ray classification.Frontiers in medicine · 2026
- Uncertainty‐suppressed long‐tailed learning with lightweight feature adaptation for multi‐label chest X‐ray classificationJournal of Applied Clinical Medical Physics · 2026