Diagnostics (Basel, Switzerland)

Inter-Slice Representation Outweighs Bounding-Box Supervision Extent in Lightweight 2.5D Pulmonary Nodule Detection: A Whole-Volume Benchmark on LUNA16.

Lien-Feng Chou, Bing-Ru Peng, Shou-Wei Chien, Yu-Ming Huang

Department of Medical Imaging and Radiological Sciences, Central Taiwan University of Science and Technology, Taichung 406, Taiwan. · Department of Information Technology, Nantou Hospital, Ministry of Health and Welfare, Nantou City 540, Taiwan.

Computational

Key points

From the paper's conclusion
  • We benchmarked the inter-slice input representation and the extent of bounding-box supervision for 2.5D pulmonary nodule detection under the official LUNA16 protocol.

Abstract

Background/Objectives: Lightweight detectors are attractive for high-throughput low-dose CT lung-cancer screening, yet the training-time choices governing their accuracy are usually fixed without justification, as is the protocol used to evaluate them. We benchmarked the inter-slice input representation and the extent of bounding-box supervision for 2.5D pulmonary nodule detection under the official LUNA16 protocol. Methods: Using one YOLO11n backbone we compared a 2D central-slice baseline, thin-slab maximum-intensity projection, and adjacent-slice 2.5D input under loose and core-focused (60% of diameter) supervision. Evaluation followed the official subset0-subset9 ten-fold protocol over all 888 scans and 1186 nodules, with whole-volume inference across 227,225 axial slices, annotations_excluded.csv applied, and paired scan-level bootstrap intervals. Supervision ratio, minimum box size, negative mining, three seeds and a YOLO26n backbone were ablated. Results: The representation dominated. Adjacent-slice input reached a competition performance metric (CPM) of 0.7795 (95% CI 0.7517-0.8005) against 0.6498 for the 2D baseline (+0.1297; 10 of 10 folds; d_z = 2.96), while thin-slab projection (0.5965) was worse than a plain 2D slice. Core-focused supervision gave no benefit (-0.0209) and no ratio improved on full-diameter supervision. Re-scoring the same checkpoints over only the slices holding an annotated nodule centre reversed the supervision result (+0.0027) and shrank the representation effect fourfold (+0.0348). Conclusions: Inter-slice representation, not supervision extent, is the dominant design factor, and the slice set searched at inference decides whether either factor is measurable.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Inter-Slice Representation Outweighs Bounding-Box Supervision Extent in Lightweight 2.5D Pulmonary Nodule Detection: A Whole-Volume Benchmark on LUNA16 — Science Skim