Inter-Slice Representation Outweighs Bounding-Box Supervision Extent in Lightweight 2.5D Pulmonary Nodule Detection: A Whole-Volume Benchmark on LUNA16.
Lien-Feng Chou, Bing-Ru Peng, Shou-Wei Chien, Yu-Ming Huang
Department of Medical Imaging and Radiological Sciences, Central Taiwan University of Science and Technology, Taichung 406, Taiwan. · Department of Information Technology, Nantou Hospital, Ministry of Health and Welfare, Nantou City 540, Taiwan.
Key points
From the paper's conclusion- We benchmarked the inter-slice input representation and the extent of bounding-box supervision for 2.5D pulmonary nodule detection under the official LUNA16 protocol.
Abstract
Background/Objectives: Lightweight detectors are attractive for high-throughput low-dose CT lung-cancer screening, yet the training-time choices governing their accuracy are usually fixed without justification, as is the protocol used to evaluate them. We benchmarked the inter-slice input representation and the extent of bounding-box supervision for 2.5D pulmonary nodule detection under the official LUNA16 protocol. Methods: Using one YOLO11n backbone we compared a 2D central-slice baseline, thin-slab maximum-intensity projection, and adjacent-slice 2.5D input under loose and core-focused (60% of diameter) supervision. Evaluation followed the official subset0-subset9 ten-fold protocol over all 888 scans and 1186 nodules, with whole-volume inference across 227,225 axial slices, annotations_excluded.csv applied, and paired scan-level bootstrap intervals. Supervision ratio, minimum box size, negative mining, three seeds and a YOLO26n backbone were ablated. Results: The representation dominated. Adjacent-slice input reached a competition performance metric (CPM) of 0.7795 (95% CI 0.7517-0.8005) against 0.6498 for the 2D baseline (+0.1297; 10 of 10 folds; d_z = 2.96), while thin-slab projection (0.5965) was worse than a plain 2D slice. Core-focused supervision gave no benefit (-0.0209) and no ratio improved on full-diameter supervision. Re-scoring the same checkpoints over only the slices holding an annotated nodule centre reversed the supervision result (+0.0027) and shrank the representation effect fourfold (+0.0348). Conclusions: Inter-slice representation, not supervision extent, is the dominant design factor, and the slice set searched at inference decides whether either factor is measurable.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Lung Nodule Detection and False Positive Reduction Using Multi-View and Background Images.Sensors (Basel, Switzerland) · 2026
- Development of a Two Stage Pipeline for Robust Pulmonary Nodule Detection in Consecutive CT Slices.Biomedicines · 2026
- Anatomical-Contextual YOLOv8-YOLOv12 Framework for Pulmonary Nodule Detection in CT: Multi-Organ Learning and Cross-Dataset Validation.Diagnostics (Basel, Switzerland) · 2026
- Quantifying the Resolution Ceiling of Prototype-Based Few-Shot Segmentation on Sub-Centimetre Pulmonary Nodules: A Training-Free Geometric Analysis.Diagnostics (Basel, Switzerland) · 2026
- Node-U-Net: A Lightweight Attention-Guided Network for Pulmonary Nodule Segmentation.Journal of imaging informatics in medicine · 2026
- MEDA-YOLO: a lightweight multi-scale edge fusion framework for pulmonary nodule detectionMeasurement Science and Technology · 2026