Ph.D. Program in Artificial Intelligence, College of Information and Electrical Engineering, Asia University, 500 Lioufeng Rd., Wufeng District, Taichung 413, Taiwan. · Department of Computer Science and Information Engineering, Asia University, 500 Lioufeng Rd., Wufeng District, Taichung 413, Taiwan.

Computational · n=80

Key points

From the paper's conclusion
  • Conclusions: Compact architectures showed competitive slice-level performance in this single-center benchmark.

Abstract

Background/Objectives: Acute cholecystitis requires timely diagnosis, yet contrast-enhanced computed tomography (CT) interpretation can be challenging under a high radiology workload. This proof-of-concept study benchmarked convolutional neural network (CNN) architectures for slice-level classification, not a clinically validated diagnostic tool. Methods: Contrast-enhanced CT from 80 patients (51 acute cholecystitis, 29 controls) at a single center (2018-2020) yielded 1060 annotated axial slices. Acute cholecystitis was defined by a Tokyo Guidelines 2018-based composite reference standard. All slices from a patient were assigned to one partition only. Six ImageNet-pretrained architectures were fine-tuned: ResNet-18/50/101, Inception-V3, MobileNet-V3-small/large. Group comparisons used Student's t test, chi-square with Yates' correction, or Fisher's exact test (R version 4.0.3; Python/SciPy). Results: On the internal held-out test set (213 slices; 122 acute-cholecystitis slices, 91 control slices), ResNet-101 achieved the highest accuracy (0.915) and specificity (0.857), while MobileNet-V3-large achieved the highest area under the curve (AUC) (0.97) and tied for the highest sensitivity (0.959) with far fewer parameters; across models, accuracy ranged from 0.812 to 0.915 and AUC from 0.89 to 0.97. Conclusions: Compact architectures showed competitive slice-level performance in this single-center benchmark. Because evaluation was slice-level in a small cohort with non-inflamed controls, these findings do not represent patient-level diagnostic accuracy. Patient-level aggregation, matched sensitivity analyses, explainability assessment, and external validation are required before clinical application.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers