Diagnostic Performance of Post-Treatment F-18 FDG PET/CT for Detecting Recurrent Cervical Cancer.
Choon-Young Kim, Sang-Woo Lee, Gun Oh Chong, Jong Mi Kim, Yoon Hee Lee, Chae Moon Hong, Shin Young Jeong
Department of Nuclear Medicine, Kyungpook National University Hospital, School of Medicine, Kyungpook National University, Daegu 41944, Republic of Korea. · Department of Nuclear Medicine, Kyungpook National University Chilgok Hospital, School of Medicine, Kyungpook National University, Daegu 41404, Republic of Korea.
Key points
From the paper's conclusion- This study evaluated the diagnostic performance of fluorine-18 fluorodeoxyglucose (F-18 FDG) positron emission tomography/computed tomography (PET/CT) for detecting recurrent cervical cancer according to clinical context.
Abstract
Background/Objectives: Cervical cancer recurrence after definitive treatment remains a major clinical challenge, and early detection may improve patient outcomes. This study evaluated the diagnostic performance of fluorine-18 fluorodeoxyglucose (F-18 FDG) positron emission tomography/computed tomography (PET/CT) for detecting recurrent cervical cancer according to clinical context. Methods: We retrospectively reviewed 1727 post-treatment PET/CT examinations obtained from 659 patients who achieved a complete response after definitive treatment between 2005 and 2024. After excluding 15 examinations that detected second primary malignancies, the recurrence-specific analysis included 1712 examinations from 654 patients. PET/CT findings were classified as true positive, true negative, false positive, or false negative based on histopathology or serial imaging follow-up. Generalized estimating equations were used to account for within-patient clustering. Subgroup analyses were performed according to histology, International Federation of Gynecology and Obstetrics (FIGO) 2009 stage, interval from treatment completion to PET/CT, and clinical context. Results: Of the 1712 examinations, 136 (7.9%) were true positive, 1525 (89.1%) were true negative, 43 (2.5%) were false positive, and 8 (0.5%) were false negative. Overall sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and accuracy were 94.4%, 97.3%, 76.0%, 99.5%, and 97.0%, respectively. Diagnostic performance was similar across histologic subtypes and FIGO stages. In routine follow-up settings without clinical suspicion of recurrence, PET/CT showed a high NPV (100.0%), whereas examinations performed for clinically suspected recurrence showed a high PPV (96.5%). Conclusions: These findings suggest that the diagnostic interpretation and clinical utility of post-treatment PET/CT may vary according to the clinical setting.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Utility of 2-[18F]Fluoro-2-deoxy-D-glucose positron emission tomography/computed tomography in assessing treatment response after chemoradiotherapy for cervical cancer.Journal of radiation research · 2026
- FDG-PET/CT-based treatment response predicts recurrence and overall survival in locally advanced cervical cancer.BMC medical imaging · 2026
- The impact and value of [18F]-FDG PET-CT on management of patients with cervical cancer with service evaluation audited against national evidence-based PET-CT guidelines.Nuclear medicine communications · 2026
- Dynamic SCC-Ag monitoring for predicting recurrence and metastasis in patients with cervical squamous cell carcinoma after definitive concurrent chemoradiotherapyFrontiers in Medicine · 2026
- Association of Complete Metabolic Response on Post-Neoadjuvant 18F-FDG PET/CT with Complete Cytoreduction in Advanced High-Grade Serous Tubo-Ovarian Carcinoma: A Retrospective Single-Center Cohort Study.Diagnostics (Basel, Switzerland) · 2026
- Association of HPV/p16 status with post-test disease risk after [18F]FDG PET/CT in oropharyngeal squamous cell carcinoma: A systematic review and meta-analysis.Oral oncology · 2026