Diagnostics (Basel, Switzerland)

Diagnostic Performance of Post-Treatment F-18 FDG PET/CT for Detecting Recurrent Cervical Cancer.

Choon-Young Kim, Sang-Woo Lee, Gun Oh Chong, Jong Mi Kim, Yoon Hee Lee, Chae Moon Hong, Shin Young Jeong

Department of Nuclear Medicine, Kyungpook National University Hospital, School of Medicine, Kyungpook National University, Daegu 41944, Republic of Korea. · Department of Nuclear Medicine, Kyungpook National University Chilgok Hospital, School of Medicine, Kyungpook National University, Daegu 41404, Republic of Korea.

Observational · n=659

Key points

From the paper's conclusion
  • This study evaluated the diagnostic performance of fluorine-18 fluorodeoxyglucose (F-18 FDG) positron emission tomography/computed tomography (PET/CT) for detecting recurrent cervical cancer according to clinical context.

Abstract

Background/Objectives: Cervical cancer recurrence after definitive treatment remains a major clinical challenge, and early detection may improve patient outcomes. This study evaluated the diagnostic performance of fluorine-18 fluorodeoxyglucose (F-18 FDG) positron emission tomography/computed tomography (PET/CT) for detecting recurrent cervical cancer according to clinical context. Methods: We retrospectively reviewed 1727 post-treatment PET/CT examinations obtained from 659 patients who achieved a complete response after definitive treatment between 2005 and 2024. After excluding 15 examinations that detected second primary malignancies, the recurrence-specific analysis included 1712 examinations from 654 patients. PET/CT findings were classified as true positive, true negative, false positive, or false negative based on histopathology or serial imaging follow-up. Generalized estimating equations were used to account for within-patient clustering. Subgroup analyses were performed according to histology, International Federation of Gynecology and Obstetrics (FIGO) 2009 stage, interval from treatment completion to PET/CT, and clinical context. Results: Of the 1712 examinations, 136 (7.9%) were true positive, 1525 (89.1%) were true negative, 43 (2.5%) were false positive, and 8 (0.5%) were false negative. Overall sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and accuracy were 94.4%, 97.3%, 76.0%, 99.5%, and 97.0%, respectively. Diagnostic performance was similar across histologic subtypes and FIGO stages. In routine follow-up settings without clinical suspicion of recurrence, PET/CT showed a high NPV (100.0%), whereas examinations performed for clinically suspected recurrence showed a high PPV (96.5%). Conclusions: These findings suggest that the diagnostic interpretation and clinical utility of post-treatment PET/CT may vary according to the clinical setting.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Diagnostic Performance of Post-Treatment F-18 FDG PET/CT for Detecting Recurrent Cervical Cancer — Science Skim