Clinical Utility of Modified Inflation-Deflation Test in Eustachian Tube Function Testing.
Dong-Hoon Lee, Yun Heo, Han-Seul Na, Seokhwan Lee, Se-Joon Oh, Sung-Won Choi
Department of Otorhinolaryngology and Biomedical Research Institute, Pusan National University Hospital, Busan 49241, Republic of Korea. · Department of Otorhinolaryngology, Gyeongsang National University Changwon Hospital, Changwon 51472, Republic of Korea.
Key points
From the paper's conclusion- These findings support the clinical utility of the MIDT as a physiological tool for assessing Eustachian tube function in patients with tympanic membrane perforation.
Abstract
Background/Objectives: The modified inflation-deflation test (MIDT) is a physiological test used to evaluate eustachian tube function in patients with tympanic membrane perforation. However, the clinical characteristics and diagnostic value of MIDT have not been fully established. This study aimed to investigate the characteristics of MIDT findings in normal function and patients with Eustachian tube dysfunction (ETD) classified by sonotubometry. Methods: We retrospectively assessed 192 ears of 181 patients with tympanic membrane perforation who underwent sonotubometry and MIDT. Based on sonotubometry findings, 117 ears were classified into the normal function group and 75 ears into the ETD group. The MIDT parameters of the groups, including the first opening pressure (OP1), first closing pressure (CP1), residual pressure after three openings (RP3), and pressure difference between OP1 and CP1 were compared. Correlation and receiver-operating characteristic (ROC) analyses were performed. Results: The ETD group had significantly higher OP1, CP1, and RP3 levels than the normal function group (all p < 0.001). The pressure difference between OP1 and CP1 was significantly greater for the normal function group. Failure of Eustachian tube opening was observed in 46.7% and 3.4% of ears in the ETD and normal function groups, respectively. Eustachian tube opening duration measured by sonotubometry was negatively correlated with OP1, CP1, and RP3 but positively correlated with the OP1-CP1 difference. ROC analysis identified an optimal cutoff value of 112.50 daPa for the OP1-CP1 difference, yielding a sensitivity of 92.3% and a specificity of 58.7%. Conclusions: MIDT was significantly associated with sonotubometry findings and effectively differentiated ETD from normal Eustachian tube function. These findings support the clinical utility of the MIDT as a physiological tool for assessing Eustachian tube function in patients with tympanic membrane perforation.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Functional Assessment Beyond Type A Tympanograms: Pressure-Swallow Testing for Chronic Eustachian Tube Dysfunction in a Taiwanese Cohort.Diagnostics (Basel, Switzerland) · 2026
- Recent Update in the Diagnosis of Eustachian Tube Dysfunction: A Comprehensive Review of the Eustachian Tube Function Test.Journal of audiology & otology · 2026
- Diagnostic Value of Tubomanometry in Patulous Eustachian Tube.Otology & neurotology : official publication of the American Otological Society, American Neurotology Society [and] European Academy of Otology and Neurotology · 2026
- Association Between Nasal Septal Deviation Types and Eustachian Tube Function: A Prospective Observational Study.The Annals of otology, rhinology, and laryngology · 2026
- History-anchored interpretation of discordant JK-05A outputs in Eustachian tube function testing.American journal of otolaryngology · 2026
- Diagnostic Performance of the Eustachian Tube Dysfunction Questionnaire-7 (ETDQ-7) in Predicting Objective Eustachian Tube Patency Among Patients with Chronic Rhinosinusitis: A Cross-Sectional Analytical Study at a Tertiary Referral Hospital in Bali, IndonesiaOpen Access Indonesian Journal of Medical Reviews · 2026