Comparing Real-Time PCR and Amplicon-Based NGS for Routine EGFR Liquid Biopsy Profiling.
Andrea Boscolo Bragadin, Valeria Tosello, Stefano Longo, Alessia Padovan, Sara Baldissin, Paola Del Bianco, Elisa Masetto, Francesco Callegarin,
Basic and Translational Oncology Unit, Veneto Institute of Oncology IOV-IRCCS, 35128 Padua, Italy. · Department of Surgery, Oncology and Gastroenterology, University of Padua, 35124 Padua, Italy.
Key points
From the paper's conclusion- Overall concordance was almost perfect (Cohen's Kappa = 0.89, 95% CI: 0.80-0.98), confirming the high reliability of both methods.
Abstract
Background: Sensitive detection of EGFR mutations in liquid biopsies of advanced non-small-cell lung cancer (aNSCLC) is vital for guiding targeted treatments. Real-time PCR offers a quick turnaround time but relatively low sensitivity while Next-Generation Sequencing (NGS) offers broader EGFR coverage, co-mutation evaluation and high sensitivity. Methods: This study evaluated the amplicon-based NGS Plasma-SeqSensei™ Solid Cancer In Vitro Diagnostics (IVD) Kit (Sysmex) against the real-time PCR-based cobas® EGFR Mutation Test v2 (Roche), the current routine standard at the Veneto Institute of Oncology IOV-IRCCS. We enrolled 130 patients with aNSCLC in the RARE Study between April 2022 and August 2025 who were referred to our institute. Liquid biopsies were taken at diagnosis or at progression and analyzed using two methods with the primary objective of assessing diagnostic concordance for EGFR profiling. Sysmex NGS libraries were sequenced on a NextSeq 550 sequencer (Illumina), with the NextSeq 500/550 Mid Output Kit v2.5 (150 Cycles) in single-end mode. Results: Among 129 evaluable samples, the NGS assay demonstrated a marginally higher EGFR mutation detection rate, identifying mutations in 31/129 cases (24.0%, 95% CI: 17-33), versus 28/129 (21.7%, 95% CI: 15-30) by cobas, specifically for variants covered by both assays. Overall concordance was almost perfect (Cohen's Kappa = 0.89, 95% CI: 0.80-0.98), confirming the high reliability of both methods. Furthermore, we identified a cfDNA input threshold of at least 20 ng as critical for ensuring optimal assay sensitivity and reliable mutation detection (Odds Ratio = 4.41 for inputs ≥ 20 ng, p = 0.006). Conclusions: Ultimately, the Sysmex NGS proved to be a robust and highly sensitive assay. It delivers performance comparable to that of standard RT-PCR while providing the clinical advantage of concurrently detecting a broader spectrum of EGFR variants and actionable mutations in other genes.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- B-120 Incremental Diagnostic Yield of Next-Generation Sequencing in NSCLC with Wild-Type Results by cobas EGFR Testing and Characterization of Rare EGFR L833V MutationClinical Chemistry · 2026
- Liquid biopsy and tissue biopsy for the detection of EGFR mutations in patients with stage III non-small-cell lung cancer: an observational real-world studyESMO Open · 2026
- Blocker Primer-Assisted LAMP Coupled with Pyrococcus furiosus Argonaute Enables Specific and Sensitive Detection of EGFR Mutations in NSCLC.Analytical chemistry · 2026
- Comparison of DNA and RNA-Based Mutation Testing for Non-Small Cell Lung Cancer.The Journal of molecular diagnostics : JMD · 2026
- Clinical Utility of Comprehensive Genomic Profiling for Advanced Non‐Small Cell Lung Cancer: A Single‐Center Retrospective StudyThoracic Cancer · 2026
- CRISPR-Cas liquid biopsy for NSCLC: analytical evidence and laboratory translation.Clinica chimica acta; international journal of clinical chemistry · 2026