Diagnostic Potential of Apparent Diffusion Coefficient-Based Lymph Node Classification in Breast Cancer Patients Undergoing [18F]FDG-PET/MRI
H A Peters, Marie Scheuer, D Weiß, Matthias Boschheidgen, Vivien Lorena Ivan, Frederic Dietzel, Svjetlana Mohrmann, Eugen Ruckhäberle,
Düsseldorf University Hospital · Essen University Hospital
Key points
From the paper's conclusion- Background/Objectives: To evaluate the diagnostic potential of apparent diffusion coefficient (ADC) values for classifying lymph nodes as benign or malignant in breast cancer patients undergoing [18F]FDG-PET/MRI staging.
Abstract
Background/Objectives: To evaluate the diagnostic potential of apparent diffusion coefficient (ADC) values for classifying lymph nodes as benign or malignant in breast cancer patients undergoing [18F]FDG-PET/MRI staging. Methods: Mean ADC values and short-axis diameters (±standard deviation) of 199 thoracic lymph nodes in 113 newly diagnosed breast cancer patients were retrospectively analyzed. All patients underwent [18F]FDG-PET/MRI staging, between July 2017 and June 2021. A node-by-node comparison was performed with respect to pathological node status. Nodal FDG uptake in whole-body [18F]FDG-PET/MRI served as reference standard for nodal malignancy. Group comparison using Mann–Whitney U test, receiver operating characteristic curve (ROC) analysis and diagnostic performance were calculated. p values below 0.05 were defined as statistically significant. Confidence intervals (CI; 95%) were calculated. Results: Ninety-three lymph nodes were FDG-negative while 106 lymph nodes were FDG-positive. FDG-negative lymph nodes had significantly lower short-axis diameters ((5.1 ± 1.5 mm versus 12.3 ± 5.3 mm); p < 0.01; U: 405.50; Z: −11.24). ADC values were significantly lower in FDG-positive lymph nodes (0.72 ± 0.14 × 10−3 mm2/s) than in FDG-negative lymph nodes ((1.18 ± 0.18 × 10−3 mm2/s); p < 0.01; U: 173.00; Z: −11.80). ROC analysis and Youden’s index revealed an ADC cut-off of 0.95 × 10−3 mm2/s (AUC: 0.98; p < 0.01; 95% CI: 0.96–1.01). According to the calculated cut-off, sensitivity, specificity, and accuracy of ADC values for differentiating FDG-negative from FDG-positive lymph nodes were 98%, 97% and 97%, respectively. Conclusions: ADC values derived from MRI were significantly associated with FDG uptake in this retrospective cohort and may serve as a complementary imaging biomarker for lymph node characterization.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Associations Between Apparent Diffusion Coefficient Values of Breast Tumors Presenting as Non-Mass Enhancement and Ki-67 Index.Cancers · 2026
- Construction of a nomogram for predicting pathological complete response of axillary lymph nodes in breast cancer after neoadjuvant chemotherapy using multiparametric MRI and clinicopathological featuresFrontiers in Oncology · 2026
- [18F]FDG PET/CT-Derived Metabolic Characteristics and Tumour-Infiltrating Lymphocytes for Predicting Axillary Response to Neoadjuvant Chemo-(Immuno)Therapy in Clinically Node-Positive Breast Cancer.Cancers · 2026
- Predictive value of preoperative [18F]FDG PET/CT imaging parameters for postoperative recurrence and metastasis in breast cancer patients.Frontiers in oncology · 2026
- Deciphering ADC disparities in breast MRI: Implications for left-right asymmetry and standardization.Clinical imaging · 2026
- Image Quality Assessment of Diffusion-Weighted Imaging (DWI) and Its Impact on Apparent Diffusion Coefficient (ADC) as a Quantitative Imaging Biomarker for Predicting Response to Neoadjuvant Chemotherapy in High-Risk Early Breast CancerTomography · 2026