Analytical Validation of a Serum Biomarker Signature for Detection of Early-Stage Pancreatic Ductal Adenocarcinoma
Robyn Pescatore, Naphtali Milliken, Thomas King, Dillon Josey, Norma A. Palma, Lisa Ford
Key points
From the paper's conclusion- We recently reported a serum biomarker signature comprising tissue inhibitor of metalloproteinase 1 (TIMP1), intercellular adhesion molecule 1 (ICAM1), cathepsin D (CTSD), thrombospondin 1 (TSP1/THBS1), and carbohydrate antigen 19-9 (CA 19-9), that detected Stage I and II PDAC with high sensitivity and specificity.
Abstract
Background/Objectives: Early detection of pancreatic ductal adenocarcinoma (PDAC) can improve patient survival and biomarkers to facilitate this are greatly needed. We recently reported a serum biomarker signature comprising tissue inhibitor of metalloproteinase 1 (TIMP1), intercellular adhesion molecule 1 (ICAM1), cathepsin D (CTSD), thrombospondin 1 (TSP1/THBS1), and carbohydrate antigen 19-9 (CA 19-9), that detected Stage I and II PDAC with high sensitivity and specificity. In this assay, CA 19-9 is measured with a commercial instrument and individual ELISAs were developed to measure TIMP1, ICAM1, CTSD, and THBS1. Here, we report the analytical performance of these four analytes in their ELISA formats. Methods: Biomarker precision, linearity, algorithm precision, matrix effects, hook effect, method comparison, interference, and analyte stability were evaluated against acceptance criteria per CLSI guidelines. Results: High, medium, and low concentrations of each biomarker met acceptance criteria for inter- and intra-day precision (%CVs < 14%) and for linearity (%CVs < 11%). Matrix effects did not impact quantitation of any analyte nor was hook effect present. All analytes met acceptance criteria for accuracy and stability (all biases < 11.2% and <16.5%, respectively). For interference, two CTSD measurements and one ICAM1 measurement in HAMA-spiked samples showed 20.7–29% biases, falling slightly outside of acceptance criteria (<20% bias). All other analyte concentrations met interference acceptance criteria. In total, 94.1% of all diagnostic calls were made with 100% certainty, indicating high precision of the assay’s algorithm. Conclusions: All analytes demonstrated acceptable analytical precision, linearity, accuracy, and stability, showing high overall analytical performance of each analyte.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Validation of a Serum-Based Biomarker Signature for Detection of Early-Stage Pancreatic Ductal AdenocarcinomaGastroenterology · 2025
- Confirmatory Clinical Validation of a Serum-Based Biomarker Signature for Detection of Early-Stage Pancreatic Ductal AdenocarcinomaCurrent Oncology · 2025
- Improving a Plasma Biomarker Panel for Early Detection of Pancreatic Ductal Adenocarcinoma with Aminopeptidase N (ANPEP) and Polymeric Immunoglobulin Receptor (PIGR)Clinical Cancer Research · 2026
- The PancreaSure Multianalyte Blood Test Performs Well at Distinguishing Early-Stage Pancreatic Ductal Adenocarcinoma from High-Risk Controls: A Retrospective Secondary Analysis.Journal of clinical medicine · 2026
- Liquid biopsy for early detection of pancreatic ductal adenocarcinoma.Nature medicine · 2026
- Circulating, Genetic, and Tissue-Based Prognostic Biomarkers for Overall Survival in Surgically Resected Pancreatic Cancer: A Systematic Review and Meta-Analysis.Medical sciences (Basel, Switzerland) · 2026