Aria Rabet, Aminreza Khandan, Arian Rabet, Mohammad Dehghan Rouzi, Fabiola Rodriguez, Adriana Garibay, David G Armstrong, Bijan Najafi
Real-time, context-aware feedback is feasible and associated with improved short-term adherence, supporting evaluation in larger trials.
BACKGROUND: Smart offloading technologies enable the real-time, objective monitoring of adherence in patients with diabetic foot ulcers (DFUs). Although remote tracking may reinforce adherence and improve wound healing, effectiveness depends on sustained device use, particularly as devices are often removed during rest periods. Real-time, behavior-contingent feedback informed by sensor data, including AI-supported messaging capable of detecting nonadherence, may enhance reinforcement. However, the feasibility and behavioral impact of such strategies remain unclear.
METHODS: We conducted a prospective feasibility case series nested within a larger DFU cohort of 210 participants, enrolling eight adults with active DFUs. Participants used a sensor-integrated offloading device paired with a smartwatch (SmartBoot) and a mobile application (CORA) that delivered notifications to their smartphones. Notifications were either schedule-based or context-aware, using real-time SmartBoot data to generate personalized messages. The primary outcome was a sensor-detected transition from nonadherent to adherent offloading within 60 min.
RESULTS: A total of 130 notifications were delivered, with 125 included in the behavioral response analysis. Context-aware notifications demonstrated higher transition rates than schedule-based notifications. Adaptive Reinforcement yielded the highest response rate (77.4%, 24/31), followed by Clinical Course Correction (71.4%, 20/28), whereas Safety and Technical Assurance (40.7%, 11/27) and Motivational Coaching (30.8%, 12/39) showed lower response rates.
CONCLUSIONS: Real-time, context-aware feedback is feasible and associated with improved short-term adherence, supporting evaluation in larger trials.