Transient Pressure-Relief Characteristics of Ethylene/Vinyl Acetate Mixtures in the High-Pressure Polyethylene Process
Yujie Hou, Xueqi Wang, Zhiyong Li, Xingqing Yan
Key points
From the paper's conclusion- The results represent comparative single-phase trends because two-phase discharge is excluded and the ethylene/VA interaction parameter remains uncertain.
Abstract
Pressure relief in high-pressure polyethylene processes involves dense, strongly non-ideal ethylene-based fluids. A transient real-fluid model was developed for the single-phase discharge of ethylene/vinyl acetate (VA) mixtures by coupling adiabatic vessel depressurization with quasi-steady isentropic nozzle flow. Thermodynamic properties were calculated using the Peng–Robinson equation of state in REFPROP. The admissible mass flux was maximized over single-phase throat states, and sonic choking was verified using ut/at ≈ 1. For the validation case at 2000 bar and 25 °C, the calculated pressure history yielded an RMSE of 120 bar, an MAE of 97 bar, and R2 = 0.93. Increasing the VA mass fraction from 0 to 40% increased the initial mass flux from 0.35 to 0.41 kg·mm−2·s−1 and shortened the single-phase duration from 761 to 413 ms. Higher initial pressure increased the mass flux, whereas higher initial temperature reduced it and prolonged discharge. The discharge coefficient affected the time scale but not the vessel isentrope or terminal state. Sonic choking occurred during the high-pressure stage, while the flux maximum became phase-boundary-limited near termination. The results represent comparative single-phase trends because two-phase discharge is excluded and the ethylene/VA interaction parameter remains uncertain.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Critical-Flow Characteristics and Mass-Flux Prediction for High-Pressure Ethylene ReliefProcesses · 2026
- Functional Testing and Numerical Analysis of Initial Freezing in Overboard Discharge Valve at Small LiftJournal of Marine Science and Engineering · 2026
- Pressure behavior in a roller pump-driven low-flow VACC mock circuit with inactive de-airing pump: A descriptive bench characterization under reduced patient-side effective filling pressure conditions.PloS one · 2026
- A Novel Equipment for VLE Studies: Ethanol and Water System at Moderate Pressures and Data Verification with a Direct Point-to-Point Test.ACS omega · 2026
- Engineering-Mechanism-Driven Modeling of High-Pressure Polymerization Processes: A Comprehensive ReviewIndustrial & Engineering Chemistry Research · 2026
- Pressure characteristics of multiphase flow in an underwater pressure vessel subject to gas injection and water dischargePhysics of Fluids · 2026