  • We compared nine ultra-high-performance concrete (UHPC) mixtures, including a plain reference and eight mixtures containing 2.0 vol% short steel, long steel, or polyvinyl alcohol (PVA) fibers in different proportions.

Abstract

We compared nine ultra-high-performance concrete (UHPC) mixtures, including a plain reference and eight mixtures containing 2.0 vol% short steel, long steel, or polyvinyl alcohol (PVA) fibers in different proportions. The equal-volume steel blend M4 had a flexural strength of 27.0 MPa and a reported fracture energy of 31.5 kJ/m2, 25.3% and 52.5% above the corresponding volume-weighted single-steel baselines. M7 had the highest reported compressive strength and elastic modulus, at 151.6 MPa and 48.0 GPa. Replacing 0.25 vol% short steel with long steel from M7 to M8 was associated with a rise in flexural strength from 29.2 to 30.4 MPa and in reported fracture energy from 35.8 to 38.6 kJ/m2. The reported compressive strength was 1.2% lower. In M8, PVA occupied 12.5% of the fiber volume and accounted for 89.3% of the calculated filament count and 45.5% of the calculated lateral interface area. The mixture comparisons suggest that longer potential steel-fiber embedment may contribute to resistance during crack opening.