Corrosion and Materials Degradation

Evaluating Microbial Corrosion Factors in a Synthetic Pipeline Benchmark and a Laboratory Calibration Case

Fei Zhao, Zhao Zhang, Xinyu Li, Rui Liu, Yangrui Zhang, Guoxi He

Computational

Key points

From the paper's conclusion
  • We compare direct and factorized prediction under an exactly known microbial multiplier and a multiplicative target law.

Abstract

We compare direct and factorized prediction under an exactly known microbial multiplier and a multiplicative target law. The revised synthetic generator couples phase flow, velocity and holdup through a common pipe area and a prescribed slip closure. Across 30 draws, complete-pipeline holdouts yielded 7950 predictions, including 1879 active cases (23.6%). With the same exact factor supplied to both extreme gradient boosting (XGBoost) procedures, grouped active root-mean-square error (RMSE) was 0.06099 mm/year for direct learning and 0.04207 mm/year for factorized reconstruction. Inactive RMSE was 0.02951 and 0.02981 mm/year, respectively. Factorization had lower pooled RMSE in 29 of 30 grouped draws and 30 of 30 random splits. Shared factor errors could reverse the active-case ranking. Factorized Ridge had pooled RMSE of 0.03061 mm/year. In a separate AH36 laboratory study, the cell-mean reference had the lowest RMSE across 16 held-out treatment-replicate means.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Evaluating Microbial Corrosion Factors in a Synthetic Pipeline Benchmark and a Laboratory Calibration Case — Science Skim