Deciphering Temperature–Humidity Coupling in Proton Exchange Membrane Fuel Cells: Multiphysics Insights into Performance, Water Management, and Operating Limits
Akram E. Zeid, Saad S. Alrwashdeh, Mohammad R. Almajali, Ahmed M. Salem, Nathan Kawansson
Key points
From the paper's conclusion- The findings demonstrate that PEMFC climate resilience is governed by the balance between hydration preservation and reactant/water transport rather than optimization of temperature or humidity independently, providing a physics-based basis for climate-adaptive control and robust hydrogen-power-system design.
Abstract
Climate-driven temperature and humidity extremes can substantially alter the coupled electrochemical, thermal, and transport processes governing proton exchange membrane fuel cell (PEMFC) performance, yet their implications for environmental resilience remain insufficiently quantified. This study develops a three-dimensional, non-isothermal multiphysics framework to assess PEMFC operation across 16 temperature–relative-humidity scenarios spanning 20–80 °C and 20–100% RH. Electrochemical kinetics, species and heat transport, membrane hydration, liquid-water behavior, oxygen availability, and spatial current-density characteristics are evaluated concurrently to identify environmentally induced operating limitations. The results reveal two competing failure regimes: hot–dry exposure promotes membrane dehydration, increased protonic resistance, spatial non-uniformity, and severe power deterioration, whereas excessive humidification progressively increases liquid-water accumulation, oxygen-transport resistance, pressure drop, and auxiliary pumping requirements. A balanced regime emerges around 60 °C and 80% RH (C11), where membrane hydration and oxygen accessibility are simultaneously maintained. Under this condition, oxygen utilization reaches approximately 79.4%, the admissible current density increases to 1.98 A cm−2, and net power density reaches approximately 1.04 W cm−2. In contrast, the hot–dry C13 condition restricts the admissible current density to 0.74 A cm−2 and reduces net power density to approximately 0.49 W cm−2. The findings demonstrate that PEMFC climate resilience is governed by the balance between hydration preservation and reactant/water transport rather than optimization of temperature or humidity independently, providing a physics-based basis for climate-adaptive control and robust hydrogen-power-system design.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Investigation of fuel cell behavior with different catalyst loadings at varying humidities and temperaturesJournal of Power Sources · 2025
- Multiphysics Modeling of Retained-Water Effects on Coupled Transport in PEM Fuel-Cell Catalyst LayersEnergy & Fuels · 2026
- Three-Dimensional Non-Isothermal CFD investigation of proton exchange membrane fuel Cells: Coupled Thermal–Electrochemical analysis and performance evaluationFuel · 2025
- Channel two-phase flow validation and dynamics in proton exchange membrane fuel cells under water-boiling-point temperature conditionsFuel · 2026
- Exergy-guided multiphysics analysis of transport irreversibilities in PEMFC flow-field architectures.Frontiers in chemistry · 2026
- Validating Multi-Parameter PEMFC Simulation Models for Vehicle Powertrain DiagnosticsFuture Transportation · 2026