Cellular Effects of a Topical Hemostatic Agent Used for Acute Bleeding Control: An in Vitro Study in MCF-7 and HEK-293 Cells.
Selçuk Eren Çanakçı, Fatih Türkmen, Ferhat Şirinyıldız, Simge Ünay, Aslı Çanakçı, Kenan Ahmet Türkdoğan
Department of Emergency Medicine, Faculty of Medicine, Aydın Adnan Menderes University, Aydın 09000, Türkiye. · Department of Emergency Medicine, Göztepe Prof. Dr. Süleyman Yalçın City Hospital, Istanbul 34722, Türkiye.
Key points
From the paper's conclusion- The results are descriptive and do not establish measured cell-survival fractions, oxidative injury mechanisms, tumor selectivity, or clinical biocompatibility.
Abstract
This exploratory in vitro study characterized 24 h responses to the topical hemostatic formulation Blood Stoper (TE'SIR) in MCF-7 and HEK-293 cells. Relative MTT reduction was assessed over 0.5-75% (v/v); qualitative scratch-gap observations and 24 h stained-cell aggregate counts were obtained in MCF-7 cells at 0.5%, 1%, and 7.5%, and supernatant malondialdehyde (MDA) and catalase readouts were obtained in both lines. In MCF-7 cells, the reported relative MTT signal declined from 72.61% at 0.5% to 15.23% at 7.5%; corresponding HEK-293 values were 114.30% and 35.44%. Images suggested impaired monolayer gap restoration, and fewer stained-cell aggregates were observed at higher exposures. Supernatant MDA and catalase readouts also varied across conditions. Inconsistencies in replication reporting, an unresolved MTT handling step, possible assay interference, and uncharacterized formulation pH, osmolality, and vehicle limit attribution of these patterns to biological effects. The results are descriptive and do not establish measured cell-survival fractions, oxidative injury mechanisms, tumor selectivity, or clinical biocompatibility. Independent validation in wound-relevant cells with formulation-matched controls is required.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Comparative preclinical evaluation of an investigational topical hemostatic formulation against an active commercial comparator in rat arterial, venous and liver bleeding models under normal and heparinized conditions.Injury · 2026
- Flexible Catechol-Conjugated Chitosan/Gelatin Bilayer Patches for Topical Hemostasis in Laparoscopic Surgery.ACS omega · 2026
- Fibrillar Cellulose-Based Hemostatic Agents for Intraoperative Bleeding Control: A Comparative Analysis of the Physical and Chemical Properties.Medicina (Kaunas, Lithuania) · 2026
- Evaluation of a Novel Chitosan-Based Hemostatic Spray in a Standard Swine Hemorrhage Model.Journal of special operations medicine : a peer reviewed journal for SOF medical professionals · 2026
- A shape-transforming hemostatic system for lethal massive hemorrhage via a confine-and-concentrate mechanism.Journal of materials chemistry. B · 2026
- Hierarchically sized chitosan hemostatic particles with electrostatic-hydrophobic synergy for rapid and effective control of arterial hemorrhage.Colloids and surfaces. B, Biointerfaces · 2026