DFT Investigation on the Adsorption and Sensing Mechanisms of Transformer Fault Gases over MOF-Based Cu-BTC and ZIF-8
Yunhua He, Yuhang Xie, Xin Zheng, Hanyu Li, Xianfeng Lang, Yongsheng Luo
Key points
From the paper's conclusion- Cu-BTC exhibits the strongest response to CO (adsorption energy: −1.745 eV, charge transfer: 0.426 e) with pronounced C-2p/Cu-3d hybridization, whereas ZIF-8 shows the strongest affinity toward C2H2 (adsorption energy: −1.986 eV); the two frameworks thus display complementary selectivity.
Abstract
Real-time detection of the six characteristic gases dissolved in transformer oil (H2, CO, CO2, CH4, C2H4, C2H2), present from sub-ppm levels for C2H2 to several thousand ppm for CO2, is essential for early fault diagnosis in oil-immersed power equipment, yet conventional metal-oxide sensors require elevated operating temperatures and suffer from poor selectivity. Density functional theory is used here to evaluate two metal–organic frameworks, Cu-BTC and ZIF-8, as room-temperature sensing candidates for these gases. Adsorption energy, charge transfer, DOS, work-function variation and temperature-dependent recovery time are analyzed for all twelve systems. Cu-BTC exhibits the strongest response to CO (adsorption energy: −1.745 eV, charge transfer: 0.426 e) with pronounced C-2p/Cu-3d hybridization, whereas ZIF-8 shows the strongest affinity toward C2H2 (adsorption energy: −1.986 eV); the two frameworks thus display complementary selectivity. Weakly bound systems desorb within microseconds to seconds at room temperature, enabling rapid regeneration, while CO on Cu-BTC and C2H2 on ZIF-8 are retained almost irreversibly and suit gas capture better. These results provide a theoretical basis for MOF-based on-line monitoring of dissolved gases in transformer oil and power-equipment fault diagnosis.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Sensing study of Fe- and Zn-doped MXene Nb2CO2 for the detection of dissolved gases H2, C2H4, and C2H2 in transformer oil: A DFT study.Journal of molecular graphics & modelling · 2026
- Adsorption and Sensing Mechanisms of Transformer Dissolved Gases on Transition Metal-Doped MoTe₂ Monolayers: A DFT StudyLangmuir · 2026
- Adsorptive Characteristics of an HfSe₂ Monolayer Functionalized with Metal Oxides (ZnO, TiO₂ ) for Sensing Transformer-Oil-Dissolved Gases (CO, H₂ , CH₄ , C₂ H₂ , C₂ H₄ )Langmuir · 2026
- Temperature-Regulated Reversible QCM and MEMS Dual-Mode Gas Sensing Based on a Thermo-/Electro-Responsive Viologen-Based Cu-MOF.Inorganic chemistry · 2026
- Mechanism-driven gas sensing in MOF and COF materials: bridging adsorption thermodynamics, electronic structure, and signal transduction.Physical chemistry chemical physics : PCCP · 2026
- Quantifying C2H2/CO2 Gas Sorption in s-Block Metal–Organic Frameworks via FTIR Spectroscopy and Periodic DFT CalculationsThe Journal of Physical Chemistry C · 2026