Cancers

Positive Esophageal Contrast from Pineapple Juice with Fat-Suppressed T2-Weighted MRI for MR-Guided Radiation Therapy: A Pilot Feasibility Study

Geina Iskander, Justin Visak, Jie Deng, Seongyeon Lee, Andrew Godley, Mu-Han Lin, Yuanyuan Zhang, Shahed Badiyan,

Key points

From the paper's conclusion
  • Conclusions: In this pilot series, thickened pineapple juice imaged with fat-suppressed T2w SPIR provided positive esophageal luminal contrast.

Abstract

Background/Objectives: Accurate delineation of the esophagus is essential for ablative radiotherapy of central lung tumors, where the esophageal wall lies within millimeters of the target. Pineapple juice is used mainly as a negative oral magnetic resonance imaging (MRI) contrast agent, and positive esophageal contrast from it has been reported only in diagnostic imaging. We assessed a positive oral contrast protocol for MR-guided radiation therapy (MRgRT) in a pilot feasibility study. Methods: Pineapple juice mixed with a food-grade thickener was imaged with T2-weighted (T2w) and fat-suppressed T2w Spectral Presaturation with Inversion Recovery (SPIR) sequences, first in a healthy volunteer at 1.5 T and then at every fraction in five patients with central lung tumors treated with online adaptive stereotactic body radiotherapy (SBRT) on a 1.5 T MR-linear accelerator (MR-Linac). In an exploratory, non-equivalent comparison, esophageal signal on T2w SPIR simulation images, normalized to each scan’s floor intensity, was compared between five patients who received the contrast and five patients with abdominal tumors imaged on the same scanner without it. Results: The preparation rendered the esophageal lumen hyperintense, most conspicuously on visual assessment with T2w SPIR, which suppresses periesophageal fat. Luminal opacification was judged sufficient for contouring at all 29 administrations and appeared consistent across patients and fractions, the maximum esophageal point dose showed no systematic increase across adaptive pulses, and no adverse effects were observed. The ratio of signal-bearing to floor-level esophageal pixels, an index defined after inspection of the data, was higher in every contrast patient than in every non-contrast patient (exact p = 0.004; after correction for the choice of thresholds, p = 0.032 one-sided and 0.063 two-sided). Conclusions: In this pilot series, thickened pineapple juice imaged with fat-suppressed T2w SPIR provided positive esophageal luminal contrast. The method offers a low-cost, well-tolerated, and technically repeatable way to visualize the esophageal lumen at each fraction of online adaptive MRgRT; whether it improves delineation of the esophageal wall, contouring accuracy, or esophageal dose remains to be tested.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers