Vascular and Circulating Blood Exposure to Proton or Photon Irradiation: Differentials in Lymphocyte Subset Metrics in Cancer Patients.
Rosa Meiriño, Felipe A Calvo, Enrique Amaya, Javier Burguete, Javier Serrano, Marina García Cardosa, Diego Pedrero, Diego Azcona,
Department of Radiation Oncology, Clínica Universidad de Navarra, 28027 Madrid, Spain. · Department of Physics and Applied Mathematics, Universidad de Navarra, 31008 Pamplona, Spain.
Key points
From the paper's conclusion- Conclusions: Patient-specific vascular delineation and dosimetry are feasible in a clinical planning workflow, and the resulting metrics track irradiation modality and the magnitude of lymphocyte depletion.
Abstract
BACKGROUND/OBJECTIVES: Radiation-induced lymphopenia is consistently associated with adverse outcomes across solid tumours, yet the vascular compartment that carries the irradiated lymphocyte pool is not routinely delineated during treatment planning. The VASA project makes blood vessels an explicit, measurable structure in that process. Phase II aimed primarily to establish the feasibility of that delineation and secondarily to explore how dose-volume metrics computed on MRI-segmented vessels relate to serial immunophenotyping in patients treated with protons or photons. METHODS: Thirty-nine patients treated between March 2021 and May 2022 were studied prospectively (30 proton, 9 photon). Flow-contrast three-dimensional MRI with three velocity-encoding directions was added to simulation; vessel masks segmented semi-automatically from the sum-of-magnitude reconstruction were imported into the treatment-planning system to generate dose-volume histograms. The effective dose to circulating immune cells (EDIC), the integral dose to vessels (IDVe) and the integral dose to target were computed. Blood was sampled at the start and at the end of irradiation for lymphocyte counts and B, T and NK immunophenotyping. Groups were compared with Welch's t-test for continuous variables and Fisher's exact test for categorical variables, without correction for multiple comparisons; the photon subgroup was not matched. RESULTS: EDIC was higher with photons than protons (5.60 vs. 1.25 Gy; p = 0.005) and in patients who became lymphopenic (4.84 vs. 1.47 Gy; p = 0.027); IDVe differed in the same direction without reaching significance (3.60 vs. 0.53 Gy·L, p = 0.091; 3.08 vs. 0.67 Gy·L, p = 0.180). Within the proton cohort, EDIC and IDVe increased from brain to head-and-neck to thorax-abdomen targets (0.81, 1.11 and 2.17 Gy; 0.13, 0.26 and 1.63 Gy·L), and the IDVe ordering persisted after adjustment for target volume (p < 0.001). Lymphocyte counts fell from 1.92 to 1.43 × 103/µL in the proton cohort (p < 0.001), with the lowest end-of-treatment values in thorax-abdomen targets (1.31 × 103/µL). B, T and NK subpopulations all declined in the proton cohort; among regions, only head-and-neck targets showed significant T and NK losses. CONCLUSIONS: Patient-specific vascular delineation and dosimetry are feasible in a clinical planning workflow, and the resulting metrics track irradiation modality and the magnitude of lymphocyte depletion. These associations are exploratory; immune-sparing plan optimisation using vascular constraints remains a future application requiring prospective validation.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Fractionated proton and photon FLASH irradiation mitigates radiation-induced lymphopenia through kinetic sparing of circulating lymphocytesbioRxiv · 2026
- Proton Therapy and Immune Preservation: Dosimetric Rationale, Clinical Evidence, and Implications for the Immunotherapy Era.Technology in cancer research & treatment · 2026
- Predictors of radiation-induced lymphopenia in NSCLC: blood and bone marrow dose during chemoradiotherapy.Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology · 2026
- Model-aided quantification of patient-specific benefit in mitigating radiation induced lymphopenia by particle therapy of cancer.International journal of radiation oncology, biology, physics · 2026
- Circulating-blood dose is associated with severe lymphopenia in thoracic radiotherapy, but added simulation complexity provides no detectable incremental information.medRxiv · 2026
- Impact of proton versus photon (chemo)radiation on circulating immune cells in head and neck cancer.Cancer research communications · 2026