Exploring the Feasibility of an Insourced 3D-Imaging Reconstruction: Preliminary Series with the Use of Synapse3D™ Software.
Daniele Fettucciari, Martina Bracco, Cristina Carerj, Filippo Gavi, Francesco Rossi, Giuseppe Pallotta, Simone Assumma, Enrico Panio,
Department of Urology, Fondazione Policlinico Gemelli Istituto di Ricovero e Cura a Carattere Scientifico-IRCCS, 00168 Rome, Italy. · Department of Urology, Ospedale Isola Tiberina-Gemelli Isola, 00168 Rome, Italy.
Key points
From the paper's conclusion- Conclusions: Insourced 3D reconstruction with Synapse3D™ is technically feasible and is learned rapidly and reproducibly by urology residents after limited training.
Abstract
Background/Objectives: To evaluate the feasibility and the learning curve of an insourced, clinician-performed three-dimensional (3D) image reconstruction workflow using Synapse3D™ software in a robotic urologic surgery setting. Methods: In this prospective single-centre case series, 20 consecutive patients scheduled for robotic kidney surgery were enrolled over a 30-day period. Three urology residents without prior experience in 3D reconstruction completed a structured two-day training programme including eight supervised practice reconstructions. Subsequently, each one reconstructed all 20 study cases independently. Reconstruction time was recorded for every reconstruction. After surgery, the two operating surgeons independently rated each model on a 5-point Likert scale for anatomical fidelity, defined as the correspondence between the model and the anatomy encountered intraoperatively. Results: All 60 reconstructions were completed successfully, with no failed reconstructions, no DICOM (Digital Imaging and Communications in Medicine) import errors and no software crashes; assistance from the manufacturer was never required. Mean reconstruction time was 19 min (range 11-29 min). Reconstruction time decreased by 0.63 min per case (95% CI 0.51-0.74; p < 0.001). Median time fell from 23 min in the first ten cases to 15 min in the last ten (p < 0.001), and the reduction was significant for each operator analysed separately. Anatomical fidelity was rated 4 (IQR 1) by both surgeons. The two surgeons rated overall system usability 3/5 and 5/5. Conclusions: Insourced 3D reconstruction with Synapse3D™ is technically feasible and is learned rapidly and reproducibly by urology residents after limited training.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- RAUL: Reference-Assisted Ureteroscopy Localization for Skill AssessmentarXiv · 2026
- Feasibility of 3D vascular reconstruction for preoperative planning in robotic living donor nephrectomy: a retrospective pilot studyFrontiers in Surgery · 2026
- Institutional availability, training resources, and supervised participation in robot-assisted surgery among Polish urology residents: a nationwide surveyJournal of Robotic Surgery · 2026
- Global landscape of robot-assisted complex ureteral reconstruction: a bibliometric and knowledge-mapping analysis.Journal of robotic surgery · 2026
- Intraoperative recall of surgeon-defined 3-dimensional planning during robotic pulmonary resection: A feasibility study.JTCVS techniques · 2026
- Three-dimensional image guidance using instrument tracking facilitates intraoperative resection-line determination during robot-assisted partial nephrectomy.Journal of robotic surgery · 2026