Effect of Eyvan Configuration on Indoor Thermal Performance in Traditional Diyarbakır Houses: Field Evidence for Climate-Responsive Passive Design
İbrahim Halil Şeker, Şefika Ergin, Berfin Şeker, Hasan Yıldızhan, Arman Ameen
Key points
From the paper's conclusion- These findings provide quantitative field evidence of the thermal benefits associated with a traditional climate-responsive spatial strategy and indicate that principles derived from eyvan design may inform passive cooling approaches in contemporary buildings in hot–dry climates.
Abstract
Traditional architecture in hot–dry regions embodies accumulated climate-responsive design knowledge that can provide useful principles for contemporary passive building design. Among the characteristic spatial elements of traditional Diyarbakır courtyard houses, the eyvan functions as a semi-open transitional space that provides shading and contributes to the thermal moderation of adjacent indoor spaces. However, in contrast to the formal and typological analyses dominant in the literature, quantitative field evidence concerning the influence of eyvan configuration on indoor thermal performance remains limited. This study investigates the thermal performance associated with three eyvan configurations, single-arched, double-arched, and triple-arched, through temperature and relative humidity measurements conducted at 30-min intervals in three traditional Diyarbakır courtyard houses during June–August. The results show that, during peak hours, the indoor temperatures of spaces adjacent to the investigated eyvans were considerably lower than the corresponding outdoor temperatures. Cooling Degree-Hour (CDH) analysis indicated lower summer temperature exceedance in the investigated building with the largest eyvan configuration. However, these differences reflect the combined thermal characteristics of the three buildings rather than the isolated effect of eyvan volume. The observations showed a consistent case-specific trend in which larger eyvan-to-room volume ratios were associated with lower indoor temperatures. These findings provide quantitative field evidence of the thermal benefits associated with a traditional climate-responsive spatial strategy and indicate that principles derived from eyvan design may inform passive cooling approaches in contemporary buildings in hot–dry climates.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Traditional Architecture and Energy Conservation: The Role of Spatial Configuration in Hot and Dry Climates.Anais da Academia Brasileira de Ciencias · 2026
- Microclimatic adaptability of alleyway in historical cultural heritage buildings based on ENVI-met simulationsnpj Heritage Science · 2025
- Courtyard Microclimates in Central Asia: Traditional Passive Cooling Strategies and Their Modern RelevanceBuildings · 2026
- An investigation into thermal comfort and daylighting in residential buildings within a subtropical highland climate: A field study in Nairobi, KenyaE3S Web of Conferences · 2026
- Impact of Courtyard Microclimate on Building Thermal Performance Under Hot Weather Conditions: A ReviewEnergies · 2025
- Passive thermal performance of vernacular dwellings in the hot summer and cold winter region of Southern Henan, ChinaCase Studies in Thermal Engineering · 2026