Buildings

High-Throughput Optimisation of Material Quantities and Embodied Carbon in 3D Reinforced Concrete Buildings in a High-Seismicity Region

Özgür Pürsünlü, Abdulkadir Çevik

Key points

From the paper's conclusion
  • This study presents an original high-throughput framework that designs 3D reinforced concrete residential buildings to the Turkish seismic code (TBDY 2018) with OpenSeesPy in about one second per design, and minimises A1–A3 embodied carbon with simulated annealing (SA) and a genetic algorithm (GA).

Abstract

Carbon-oriented seismic design optimisation has mostly been applied to single, regular, two-dimensional frames, rarely to shear-wall layouts or code-defined irregularities, seldom with a check against a known global optimum, and its results are seldom expressed in the material quantities that design offices use. This study presents an original high-throughput framework that designs 3D reinforced concrete residential buildings to the Turkish seismic code (TBDY 2018) with OpenSeesPy in about one second per design, and minimises A1–A3 embodied carbon with simulated annealing (SA) and a genetic algorithm (GA). Forty-five archetypes (4–12 storeys, moment frames and four shear-wall layouts, three irregularity types) were optimised for a high-seismicity site in Kahramanmaraş in over 600 runs on one workstation. The models agree with ETABS within 1% for frames and 5% for walled buildings. For this archetype set, the optimised designs used 11% less concrete, 6.5% less reinforcement, and 9% less formwork than code-compliant conventional sizing and emitted 10% less carbon (7.5–11.5%, depending on height, lateral system, and irregularity). The lowest permitted concrete class was always optimal, also at reduced hazard, and B500C reinforcement cut steel by a further 13%. GA found the same optimum in every seed, and exhaustive enumeration of 232,064 designs for nine 8-storey archetypes confirmed it as the global optimum; SA missed it in 9 of 225 runs. The resulting design rules need no optimisation software: size members to the governing code limit, use the lowest permitted concrete class with B500C and blended cement, avoid eccentric wall layouts, and minimise carbon rather than concrete volume.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

High-Throughput Optimisation of Material Quantities and Embodied Carbon in 3D Reinforced Concrete Buildings in a High-Seismicity Region — Science Skim