Mechanical Properties of PBL Connectors in CA-UHPC Specimens Under Sustained Loading
Hongxu Cui, Zongxiao Yang, Runsheng Pei, Jikang Tie, Yulong Zheng, Jinda Li
Key points
From the paper's conclusion- To investigate the effect of sustained loading on the mechanical properties of perfobond leiste (PBL) shear connectors in coarse aggregate ultra-high-performance concrete (CA-UHPC) specimens, 180-day sustained-loading tests followed by ultimate push-out tests were conducted on six specimens, with one specimen representing each configuration, to evaluate the effects of steel plate thickness, hole d
Abstract
To investigate the effect of sustained loading on the mechanical properties of perfobond leiste (PBL) shear connectors in coarse aggregate ultra-high-performance concrete (CA-UHPC) specimens, 180-day sustained-loading tests followed by ultimate push-out tests were conducted on six specimens, with one specimen representing each configuration, to evaluate the effects of steel plate thickness, hole diameter, transverse reinforcement, concrete strength, and connector type. The results indicate that under sustained loading, the relative slip between the steel plate and the CA-UHPC develops rapidly during the initial stage and gradually stabilizes thereafter. The 180-day cumulative slip increments of the larger-hole and thicker-plate specimens were 19.2% and 26.9% lower, respectively, than those of the standard specimen. However, the individual sustained-load ratios were not identical. In particular, the calculated load ratio of the thicker-plate specimen was 39.08%, compared with 32.34% for the standard specimen. Therefore, the observed differences should be interpreted in the context of the adopted paired-loading protocol rather than attributed solely to the corresponding geometric parameters. Compared with the short-term reference results, the specimens tested after 180 days of sustained loading exhibited lower ultimate shear capacities and initial shear stiffnesses, with the differences varying according to connector configuration and material properties.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Numerical Investigation of the Shear Performance of Large-Diameter Hinged-Bolt Connectors in Steel–UHPC Composite BeamsBuildings · 2026
- Bonded and Unbonded Length Allocation in UHPC-Grouted Corrugated Duct Connections: Anchorage Slip and Reinforcement Strain in Precast Bridge ColumnsBuildings · 2026
- Mechanism-Based and Experimentally Calibrated Modelling Strategy for Prestressed I-Shaped UHPFRC-Steel Composite Beams with Continuous Shear Connectors.Materials (Basel, Switzerland) · 2026
- Interface shear behaviour of ultra-high performance concrete under combined shear and lateral loadsEngineering Structures · 2025
- Investigation of direct shear behavior at UHPC interfaces incorporating high-strength steel lap jointsStructures · 2025
- Comparative bond characteristics of polymer concrete and UHPC for bridge joints: Reinforcement anchorage and substrate interface behaviorConstruction and Building Materials · 2026