Buildings

Temperature Prediction and Fatigue Assessment of District Heating Pipelines Using a DNN–LSTM Hybrid Model

Yaqian Wang, Chongfang Song, Wuxuan Pan, Zihang Cheng, Xi Chen, Yonggang Lei

Key points

From the paper's conclusion
  • These conditional calculations show that pointwise temperature accuracy and total cycle agreement do not establish fatigue damage agreement; local weld damage and remaining life require further validation.

Abstract

This study compared DNN–LSTM, RF, and XGBoost temperature prediction using six heating season records and then optimized the selected DNN–LSTM model with PSO. At forecast origin t, 24 h of available inputs were used to predict temperature at t + 60 min. The primary supply test R2 was 0.9909 and MAPE was 0.79%. For fatigue assessment, the available six-year measured and predicted primar -network temperature series were cleaned and separately subjected to sequential rainflow counting. The six-year values were scaled by a factor of five to obtain 30-year equivalent values. Under a nominal fully restrained thermal stress model and a base metal S–N parameter, predicted 30-year damage was 6.066 × 10−7 versus 1.698 × 10−6 from measured supply temperature and 1.363 × 10−7 versus 2.563 × 10−7 from measured return temperature, corresponding to differences of −64.28% and −46.80%. These conditional calculations show that pointwise temperature accuracy and total cycle agreement do not establish fatigue damage agreement; local weld damage and remaining life require further validation.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers