Non-Destructive Identification of Artificial Surface Cracks in Concrete Using Coupled Time–Frequency Multi-Dimensional Features
Shouqi Zhang, Fei Zhao, Yaqi Zhou, Wenlong Zhang, Jinghan Zhang, Sitong Xin
Key points
From the paper's conclusion- These results indicate that the extracted time–frequency features exhibit good stability and discriminability under the current experimental conditions and that the systematic decrease in the average parameters can serve as a macroscopic criterion for the presence of damage.
Abstract
The identification of internal cracks in concrete structures is crucial for ensuring engineering safety. However, traditional non-destructive testing often relies on single time-domain amplitude indicators, which are prone to missed detections due to the scattering interference of heterogeneous materials. To address this, this study proposes a non-destructive identification method based on time–frequency multi-dimensional feature coupling. In the experiment, a robotic arm-driven excitation source was used to apply vertical impacts on a 400 mm × 100 mm × 100 mm concrete specimen. A dual-row parallel sensor array was deployed, and a fully digital acoustic emission system was utilized to collect time–frequency parameters in streaming mode. This study breaks the commonsense conjecture of traditional linear attenuation, discovering that although the time-domain amplitude of the cracked specimen maintains a monotonic decrease macroscopically, its dominant frequency evolution exhibits severe jumping and spatial disorder, leading to the asymmetrical and disordered expansion of the multi-dimensional difference radar chart. This time–frequency asynchronous distortion can be explained as resulting from the combined action of the contact acoustic nonlinearity (CAN) effect at the crack interface and multipath diffraction superposition; this CAN effect still requires further experimental verification. This achieves the upgrade from an extensive energy attenuation criterion to a refined nonlinear feature coupling criterion. Method verification was completed based on artificial surface cracks, providing data support and methodological reference for subsequent research on the detection of concealed cracks and internal damage in concrete. Experimental results show that the average response voltage of the intact specimen was approximately 37,110.82 mV and decreased to 21,807.43 mV for the damaged specimen, corresponding to a reduction of about 41.2%. The coefficients of variation (CV) were 0.5867 and 0.5884, respectively, with a difference of only about 0.0017. Damage mainly caused an overall downward shift in the feature mean, while the relative degree of dispersion remained essentially unchanged. These results indicate that the extracted time–frequency features exhibit good stability and discriminability under the current experimental conditions and that the systematic decrease in the average parameters can serve as a macroscopic criterion for the presence of damage.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Signal-Processing Procedure for Preliminary Concrete Anomaly Screening Based on Continuous Sliding Acoustic Excitation.Sensors (Basel, Switzerland) · 2026
- Field and Numerical Investigation of Impact-Echo Responses for Internal Defect Assessment in Cylindrical Concrete Bridge PiersBuildings · 2026
- Measurement and Characterization of Corrosion-Induced Cracking in Reinforced Concrete: A ReviewBuildings · 2026
- Determination of Micro-Events and Microcracks in the Compressive Strength of Concrete Using the 3D Acoustic Spectrum in the Low Frequency and Infrasound.Materials (Basel, Switzerland) · 2026
- Nonlinear Wave Mixing Approach for Internal Damage Localization in Concrete.Sensors (Basel, Switzerland) · 2026
- Impact-echo data and crack classification of six prestressed reinforced concrete sleepers of type B70.Data in brief · 2026