Flexural and Shear Behaviour of Post-Tensioned Paper-Tube Voided Slabs and a Design Criterion for Tendon Substitution
Inkwan Paik, Seongju Maeng, Sungho Yun, Dongkwan Kim, Daekyung Kim, Seunguk Na
Key points
From the paper's conclusion- This study examines 32 full-scale one-way slab specimens, comprising 20 flexural and 12 shear tests, with solid and paper-tube voided sections, three formwork configurations, and post-tensioned variants.
Abstract
Voided slabs reduce self-weight by removing concrete near the neutral axis, but the interaction between continuous cylindrical voids and post-tensioning remains poorly understood because the voids restrict the tendon position, and hence, its available lever arm. This study examines 32 full-scale one-way slab specimens, comprising 20 flexural and 12 shear tests, with solid and paper-tube voided sections, three formwork configurations, and post-tensioned variants. Archived load records were reconciled against the raw load-cell signal and cross-checked using reinforcement-strain measurements. In flexure, voids occupying 33–42% of the gross section as drawn (22.7–34.9% on a nominal two-tube basis) changed peak load by only +3.7% on average, consistent with the limited sensitivity of flexural strength to concrete removal near the neutral axis. Post-tensioning produced no systematic increase in peak load because the tube geometry restricted the tendon depth and reduced its lever arm relative to the bars it replaced. A closed-form, section-level screening check was developed to quantify this geometric limitation. In the two controlled shear pairs, the solid specimens yielded in flexure before peak, whereas their voided companions failed in diagonal tension; voiding reduced peak load by 19.2% and 38.0%, whereas the measured work to peak decreased by 81.9% and 91.3%. These results indicate that continuous cylindrical voids may impair pre-peak deformation capacity more severely than peak shear resistance at low shear-span-to-depth ratios.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Numerical Investigation of Unbonded Post-Tensioned Concrete Slabs Reinforced with CFRP TendonsCivilEng · 2026
- Comparative Study on Shear Reinforcement Performance of Prestressed Concrete Hollow Slab Beams in Existing HighwaysEngineering Reports · 2026
- Comparative Structural Behavior of Sustainable Fibrous Voided Ferrocement Slabs Incorporating Waste Glass Powder and Different Void FormersEng · 2026
- Numerical investigation on influence of segmental joint weakening in prestressed concrete continuous rigid frame bridgeJournal of Physics: Conference Series · 2026
- Analysis of the shear deformation in simply supported prestressed concrete girder-bridgesProcedia Structural Integrity · 2026
- Flexural behavior and crack development of reinforced geopolymer slabs with longitudinal voids: an experimental studyScientific Reports · 2026