Experimental Investigation of the Arching Effect and Joint Optimization of a Timber-Pile-Supported Mulberry Branch Bundle Arch Revetment
Yongfeng Guo, Xiaohui Wang, Yiqi Yang, Siyuan Xu, Xingyu Wu, Xiaojuan Yu
Key points
From the paper's conclusion- In the rise-direction compression tests, the combined horizontal-vertical mulberry branch bundle arch configuration (CA) reached a mean peak load of 5.384 kN, which was 12.0% higher than that of HA (4.807 kN), whereas HA exhibited a more stable post-peak response.
Abstract
Conventional rigid revetments provide limited ecological functions, while flexible biomass-based systems often lack adequate load-bearing stability. This study developed a timber-pile-supported mulberry branch bundle arch revetment and investigated the effects of bundle arrangement, joint restraint, and rise-to-span ratio on structural deformation, load transfer, and load-bearing performance. Staged model-box loading tests, rise-direction compression tests, joint-optimization validation tests, and rise-to-span ratio tests were conducted, and the support-transmitted forces and equivalent eccentric-compression characteristics were analyzed. Among the four basic configurations tested using scaled specimens, the horizontal mulberry branch bundle arch configuration (HA) exhibited the smallest horizontal deformation. In the rise-direction compression tests, the combined horizontal-vertical mulberry branch bundle arch configuration (CA) reached a mean peak load of 5.384 kN, which was 12.0% higher than that of HA (4.807 kN), whereas HA exhibited a more stable post-peak response. The combined joint optimization scheme, comprising solid trapezoidal timber joints, contact surface flattening, geotextile interfaces, and restraining nails, reduced the cumulative horizontal displacement of HA by 14.3–16.7% and increased its mean peak load by 26.96%, without separately evaluating the contribution of each modification. The support-force measurements and equivalent eccentric-compression analysis provided support-level evidence of relatively balanced bilateral compressive support and arch-type load transfer in the optimized HA. For rise-to-span ratios of 0.2, 0.3, and 0.4, the corresponding mean peak loads were 4.487, 6.917, and 2.260 kN, respectively, with 0.3 showing the most favorable overall mechanical response among the three tested ratios under the present experimental conditions. These results highlight the combined influence of bundle arrangement, joint configuration, and rise-to-span ratio on the mechanical response under the tested conditions.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Bio-Inspired Suture Joints Enable Tuned Load Transfer in Digitally Fabricated Timber with Hybrid Thermoplastic Connectors.Biomimetics (Basel, Switzerland) · 2026
- Holz‐Granit‐Verbundkonstruktionen für Geh‐ und Radwegbrücken – Teil 1Bautechnik · 2026
- Comparison and selection of ecological revetments for urban rivers using the AHP-based fuzzy evaluation and TOPSIS methodsDiscover Applied Sciences · 2026
- Moment-resisting timber frames using mechanical fastener and adhesive connections: review and experimental testsCanadian Journal of Civil Engineering · 2026
- Verformungsverhalten und Lastaufteilung einer Rigid‐Inclusion‐Gründung (System CMC)geotechnik · 2026
- COMPATIBLE ANCHORING SYSTEMS OF TEXTILE MEMBRANES IN ARCHITECTURAL HERITAGE: THE CASE STUDY OF COURTYARDS ROOFINGce/papers · 2026