Buildings

Parametric Analysis and Simplified Design Method for Multi-Layer Composite Confinement Structures Under Internal Blast Loading

Pengfei Ning, Bo Yan, Degao Tang

Key points

From the paper's conclusion
  • Multi-layer composite confinement structures (MLCCSs) are critical for containing accidental internal explosions, yet conventional design methods cannot capture their three-layer load-redistribution mechanism.

Abstract

Multi-layer composite confinement structures (MLCCSs) are critical for containing accidental internal explosions, yet conventional design methods cannot capture their three-layer load-redistribution mechanism. Based on a validated fluid–structure interaction (FSI) model, this study investigates four key parameters (the foam-concrete yield strength, interlayer thickness, inner-layer reinforcement ratio, and inner-layer thickness) under 3 and 5 kg TNT charges and develops a simplified design method for MLCCSs with a foamed-concrete interlayer under internal blast. The foam yield strength is found to be the most critical parameter controlling the Mode I/II transition: increasing it reduces the inner-layer displacement but increases the risk of premature outer-layer yielding, challenging the conventional “stronger-is-better” design philosophy and establishing both upper and lower bounds for the foam yield strength. The method is derived from a rigid–plastic inner-layer model and the load-controllability mechanism of the foam interlayer, yielding closed-form expressions for the inner-layer maximum displacement, the minimum required interlayer thickness, and the outer-layer peak hoop strain. The inner-layer maximum displacement is quantitatively validated, with a mean absolute error of 9.50%, while the three remaining outputs are checked for consistency with the numerical results; because the Mode I/II threshold is calibrated from the same numerical dataset, this consistency check is an internal self-consistency test rather than an independent validation of the strain prediction. A step-by-step design procedure incorporating the Mode I/II criterion is proposed and demonstrated on a prospective design example whose configuration is not among the calibration cases. The study provides a rapid screening tool for the preliminary design of MLCCSs.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Parametric Analysis and Simplified Design Method for Multi-Layer Composite Confinement Structures Under Internal Blast Loading — Science Skim