Infrared Thermography-Based Assessment of Thermal Bridges and In Situ Thermal Performance in Occupied Precast and Reinforced Concrete Apartment Buildings
Na-Young Joo, Seung-Yeong Song
Key points
From the paper's conclusion- These findings are expected to provide useful baseline data for post-occupancy performance assessment and improvement in envelope design for off-site construction (OSC)-based PC residential buildings.
Abstract
In this study, infrared thermography (IRT) was used to quantitatively evaluate the thermal bridge characteristics and in situ thermal performance of exterior wall-to-floor junctions in occupied precast concrete (PC) and reinforced concrete (RC) apartment buildings with different exterior wall systems. Three representative PC apartment buildings with different exterior wall systems were investigated under winter nighttime conditions. IRT was used to qualitatively assess thermal bridge characteristics in all three buildings, while the in situ thermal performance of one representative case was quantitatively evaluated by estimating the effective thermal transmittance (U-value) from infrared surface temperature measurements based on heat transfer theory. The estimated U-value was validated using three-dimensional heat transfer simulations. The results showed that exterior wall-to-floor junctions were major heat-loss pathways in all cases, while the thermal bridge patterns varied depending on the exterior wall system and continuity of insulation. In Case 3, the PC curtain wall system with improved insulation continuity exhibited less pronounced thermal bridging than the corresponding RC system. The IRT-estimated Ueff was 0.379 W/m2·K for the PC building and 0.661 W/m2·K for the RC building, representing a 42.7% lower value for the PC building. The corresponding simulated values were 0.407 and 0.514 W/m2·K, with differences between the IRT-estimated and simulated values of 7.4% and 22.2%, respectively. These findings are expected to provide useful baseline data for post-occupancy performance assessment and improvement in envelope design for off-site construction (OSC)-based PC residential buildings.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Addressing uncertainty in U-value estimation with infrared thermography: A Kriging-based model calibration approachEnergy and Buildings · 2025
- Uncertainty-aware determination of thermal transmittance and systematic evaluation of insulation retrofit scenarios for energy-efficient building envelopeJournal of Thermal Analysis and Calorimetry · 2026
- A field framework for U-values and dynamic response in prefabricated rural dwellings: theory–measurement gaps and ranking reversalEnergy and Buildings · 2026
- Calculation model for the thermal conductivity of concrete considering microstructural characteristicsCase Studies in Thermal Engineering · 2026
- Comparative Analysis of Thermal Bridges and Condensation Risk Based on Installation Positions of Single- and Double-Window Systems in Externally and Internally Insulated Concrete WallsBuildings · 2026
- Thermal bridging in buildings: A critical review of mechanisms, mitigation strategies, energy impacts, and research needsBuilding Services Engineering Research and Technology · 2026