Field Measurements of Adaptive Thermal Comfort in Naturally Ventilated Homes of Malaysia’s Hot–Humid Climate
Yuriny Adnan, Najiha Jaffar, Halim Razali, Lok Kuang Wooi, Chin Haw Lim
National Institutes of Biotechnology Malaysia · National University of Malaysia
Key points
From the paper's conclusion- Overall, the results demonstrate that combinations of low air velocity (<0.10 m/s) and elevated mean radiant temperature (>30 °C) consistently drive operative conditions beyond the upper 90% adaptive comfort threshold, confirming ventilation effectiveness is the primary control factor of thermal acceptability in tropical residential environments.
Abstract
Hot and humid climates challenge conventional residential designs in maintaining thermal comfort, often leading to a heavy reliance on energy-intensive mechanical cooling. This dependence increases operational costs and contributes to elevated carbon emissions. In rapidly urbanising regions such as Selangor, Malaysia, climate-responsive and sustainable design strategies are urgently needed. This study evaluates the effectiveness of passive design strategies in enhancing indoor thermal comfort in naturally ventilated residential buildings using a three-case study methodology. Empirical field measurements were conducted to examine the influence of shading, building orientation, natural ventilation, and material selection on operative temperature Top and perceived comfort. The findings indicate that integrating passive strategies significantly improves indoor thermal conditions. Residence A, incorporating effective cross-ventilation and thermal mass, achieved the lowest operative temperature range of 28.5 °C to 29.8 °C, remaining within the 90% adaptive comfort band, with favourable air velocities between 0.45 and 0.65 m/s. In contrast, Residence B recorded higher operative temperatures from 29.5 °C to 31.2 °C, up to 1.4 °C warmer than Residence A, due to mean radiant temperatures exceeding 31 °C and a near-stagnant airflow below 0.10 m/s. Although Residence C demonstrated moderated radiant temperatures between 28.2 °C and 29.5 °C through effective envelope design, operative temperatures remained warm, ranging from 29.0 °C to 30.5 °C, due to severely restricted air velocities below 0.05 m/s. Overall, the results demonstrate that combinations of low air velocity (<0.10 m/s) and elevated mean radiant temperature (>30 °C) consistently drive operative conditions beyond the upper 90% adaptive comfort threshold, confirming ventilation effectiveness is the primary control factor of thermal acceptability in tropical residential environments.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- A systematic review of passive design strategies for modular stacked housing in warm-humid climatesFrontiers in Built Environment · 2026
- Urban morphology for passive–active energy efficiency in residential complexes: a scoping review and framework for early-stage design in the MENA regionFrontiers in Sustainable Cities · 2026
- Optimal Passive Interventions for Enhancing Resilience of Naturally Ventilated Residential Buildings in Future Climatic ExtremesBuildings · 2025
- Semi-outdoor workspace in the tropics: Exploring thermal comfort through field measurements and surveysIndoor Environments · 2025
- Long-Term Indoor Hygrothermal Performance at Room Level in Occupied Residential Apartments Under a Hot Arid Coastal Climate: Implications for Sustainable Building PerformanceSustainability · 2026
- Harnessing Thermal Stress for Sustainable Zero-Energy Building Design in IraqGreen Technology & Innovation · 2026