Impact of Facade Photovoltaic Retrofit on Building Carbon Emissions for Residential Buildings in Cold Regions
Yujun Yang, Xiao Li, Zihan Yao, Ann T.W. Yu, Miyang Wang
Xi'an Jiaotong University
Key points
From the paper's conclusion- For multi-story buildings, a full façade retrofit yielded the highest annual electricity generation of 514,703.56 kWh and an annual carbon reduction of 15,521.50 kgCO2.
Abstract
China’s urbanisation has transitioned from an era of rapid, coarse expansion to one of refined and targeted development. In accordance with China’s “dual-carbon” strategy, the building sector—presently the third-largest source of domestic carbon emissions—is compelled to pursue emission optimisation in its forthcoming evolution. Photovoltaic-building technologies offer an effective response to this imperative. Within the context of accelerating high-rise residential construction, the architectural integration of scientifically configured photovoltaic façades has emerged as a critical challenge. Employing an integrated methodology of urban surveying and simulation, this study examines the façade characteristics of residential buildings in northern Chinese cities, selecting Xi’an as the representative case. Three PV-facade integration strategies for existing stock are presented: window retrofitting, wall retrofitting, and full-façade renovation. Utilising the EnergyPlus platform, the manuscript simulates the electrical demand profiles and clean-electricity generation of typical dwellings under varying photovoltaic materials and configuration schemes, while concurrently assessing economic performance. It demonstrates that a judicious determination of photovoltaic installation scale and layout strategy markedly amplifies energy-saving efficacy, diminishes aggregate energy consumption and carbon emissions, and simultaneously reduces the capital expenditure of photovoltaic systems. For multi-story buildings, a full façade retrofit yielded the highest annual electricity generation of 514,703.56 kWh and an annual carbon reduction of 15,521.50 kgCO2. For high-rise buildings, installing PV modules only above the 20th floor increased the effective generation ratio from 45.24% to 87.17%, while the carbon reduction efficiency per unit investment improved from 0.05 to 0.22 kgCO2/¥.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Towards low-carbon cities with envelope-integrated photovoltaic-thermal systems: A multi-scale techno-economic appraisalEnergy · 2026
- Can photovoltaic retrofit redefine heritage value? Practical and theoretical evidence from meta-analysis and multi-criteria evaluation of 133 international case studies over 35 yearsJournal of Cleaner Production · 2026
- Multi-Objective Performance Assessment and Pareto Screening of Energy Use, Photovoltaic Generation and Life-Cycle Cost for New Rural Housing Across Five Chinese CitiesBuildings · 2026
- Simulation-based assessment of PV integration on complex roof geometries in Nordic climates: Building-scale analysis and neighborhood-scale implicationsE3S Web of Conferences · 2026
- Solar energy for multi-story apartment buildings – Innovative façade solutions and energy sharing enable load-matchingEnergy and Buildings · 2026
- Photovoltaic material selection and multi-objective building design optimization for enhancing energy performance of building integrated photovoltaics (BIPV) systemsApplied Energy · 2025