Image-Level Classification of Central Vein Categories on FLAIR MRI in Multiple Sclerosis Using a Lightweight Explainable Deep Learning Framework.
Irem Tasci, Gozde Elidar, Sait Albayrak, Omer Faruk Goktas, Turker Tuncer, Mehmet Baygin, Fatma Ebru Algul, Burak Tasci,
Department of Neurology, School of Medicine, Firat University, Elazig 23119, Türkiye. · Department of Neurology, Elazig Fethi Sekin City Hospital, Elazig 23280, Türkiye.
Key points
From the paper's conclusion- We developed a compact convolutional neural network (CNN) and a deep feature engineering (DFE) pipeline for three-class classification of clinically labeled MR images.
Abstract
Background/Objectives: The central vein sign can help characterize multiple sclerosis (MS) lesions on MRI, but reading it takes specialist time and experience. We developed a compact convolutional neural network (CNN) and a deep feature engineering (DFE) pipeline for three-class classification of clinically labeled MR images. Methods: The MS Vein dataset contains 3181 axial FLAIR images from 154 participants in vein-positive, vein-negative, and control classes. MACDIBNeXt (about 6.5 million parameters) combines pooling-based attention downsampling, grouped convolution, and bottleneck and inverted bottleneck blocks. It was pretrained on Stable ImageNet1k and fine-tuned on a participant-level split (98 training, 25 validation, and 31 test participants). The DFE pipeline extracted 768 global average pooling features, selected 47 with CWINCA in participant-grouped folds of the training data, and classified them with tkNN. Results: On 635 held-out test images from 31 participants, the standalone CNN classified 527 correctly (82.99%; participant-cluster bootstrap 95% CI, 77.93-87.66%). DFE classified 571 correctly (89.92%; 85.47-93.82%), with 89.13% macro F1 and Cohen's κ of 0.83. With participants resampled as clusters, the 6.93-point gain had a 95% CI of 3.33-10.63 points (p = 0.0002), and a cluster-adjusted McNemar test gave p = 0.0021. Grad-CAM activation was intracranial in the displayed examples. Conclusions: MACDIBNeXt with DFE gives promising internal, image-level results. Because the data are retrospective, single-center, and labeled on FLAIR images, external participant-level validation is required before clinical use.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- A Central-Vein-Sign-Aware Deep-Learning Pipeline for Lesion Detection and Automated CVS Assessment on Brain SWIp: An Exploratory End-to-End Feasibility Study.Journal of imaging · 2026
- DenseGated-MSNet: A Multi-Sequence Gated Fusion Network for Multiple Sclerosis Classification from Brain MRI.Diagnostics (Basel, Switzerland) · 2026
- MICAFlow: Fast and robust MRI preprocessing bridging research neuroimaging and clinical practice.Imaging neuroscience (Cambridge, Mass.) · 2026
- Revisiting the MS paradox: automated 2.5D FLAIR segmentation and DTI microstructural profiling reveals dissociation between lesion burden and reference-like intralesional tract profiles.Frontiers in human neuroscience · 2026
- Performances of experts and automated methods on new multiple sclerosis lesions detection: insights from the MSSeg2 challengeScientific Reports · 2026