From the paper's conclusion- The composite provides a tunable, reduced-concentration absorption standard for wavelength-specific calibration of NIR Hct sensors, best used within a defined period after preparation.
Abstract
Optical tissue phantoms are essential for biomedical spectroscopy and sensor calibration, particularly for non-invasive hematocrit (Hct) sensing, for example, in dengue, where hemoconcentration signals plasma leakage. Reproducible blood-mimicking hydrogels with tunable, Hct-graded absorption and a temporally stable matrix remain challenging to develop. Agarose, gelatin and agarose–gelatin composite matrices were evaluated for background absorption, spectral neutrality, homogeneity and stability over 40 h. A composite of 0.15% agarose and 4% gelatin gave a featureless near-infrared (NIR) background (μa ≤ 0.015 cm−1 at 805 nm) and lower optical drift than either single-polymer matrix. Ten Hct-graded phantoms (10–90% equivalent) containing dissolved bovine hemoglobin (2.1–23.4 g/L) were characterized by transmission spectrophotometry at 740, 805, 900 and 940 nm. Absorption was linear in hemoglobin loading at all wavelengths (R2 = 0.9999), and two independent preparations agreed within 5.8–8.0% (mean absolute deviation), equivalent to between-series prediction deviations of 2.7–4.4 Hct points. Phantom absorption was about one tenth that of whole blood and spectrally flatter: per gram of hemoglobin, it matched oxygenated whole blood at 900–940 nm (0.93–1.04×) but exceeded it at 740 and 805 nm, consistent with non-oxygenated hemoglobin species. Hemoglobin-loaded phantoms drifted by up to 26% over 40 h at intermediate Hct. The composite provides a tunable, reduced-concentration absorption standard for wavelength-specific calibration of NIR Hct sensors, best used within a defined period after preparation.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Forensic evaluation of blood-mimetic engineered simulants derived from colloidal approachFrontiers in Materials · 2026
- Hemocompatible polymeric hydrogels with tunable photoresponsive volumetric propertiesFrontiers in Biomaterials Science · 2026
- A Skin-Compatible Carboxymethyl Cellulose-Reinforced Gelatin Hydrogel with High Adhesion and Low Impedance for High-Fidelity Electrocardiogram Monitoring.ACS applied materials & interfaces · 2026
- Research on Intraoperative Non-Invasive Hemoglobin Detection Technology Based on Four-Wavelength PhotoplethysmographyBiosensors · 2026
- Systematic Benchmarking of a Noise‐Tolerant Conductive Hydrogel Electrode for Epidermal BioelectronicsAdvanced Science · 2025
- Covalently Functionalized Click Alginate Cryogels Enable Non-Invasive Near-Infrared Sensing of Gastric pHbioRxiv · 2026