Chip-Integrated Optical Modulation Biosensing with Microfluidic Background Reduction for High-Sensitivity Fluorescence Immunoassays.
Shmuel Burg, Meir Cohen, Reut Ashkenazy, Sophie Terenteva, Yaniv Lustig, Viki Indenbaum, Ravit Koren, Tran Mai Hoa,
Faculty of Engineering, The Institute of Nanotechnology and Advanced Materials, Bar-Ilan University, Max and Anna Webb Street, Ramat Gan 5290002, Israel. · Central Virology Laboratory, Israel Ministry of Health, Chaim Sheba Medical Centre, Tel-HaShomer, Ramat Gan 5262000, Israel.
Key points
From the paper's conclusion- Here, we present chip-based optical modulation biosensing (Chip-OMB), combining three-dimensional magnetic bead-based target capture, bead immobilization, internal fluid flushing, and modulated optical background subtraction.
Abstract
Microfluidic fluorescence immunoassays enable sensitive biomarker detection, but performance is limited by inefficient capture on planar surfaces and background fluorescence from unbound labels. Here, we present chip-based optical modulation biosensing (Chip-OMB), combining three-dimensional magnetic bead-based target capture, bead immobilization, internal fluid flushing, and modulated optical background subtraction. Magnetic beads are concentrated and immobilized in the chamber, while controlled on-chip flushing displaces unbound fluorescent labels without requiring user-performed washing after chip loading. Alternating optical interrogation of the bead cluster and surrounding solution enables background subtraction. Using fluorescently labeled magnetic beads, Chip-OMB achieved limits of detection of 0.1 pM in buffer and 22 pM in undiluted plasma, corresponding to 580-fold and 22-fold lower equivalent fluorophore-concentration limits of detection, respectively, than conventional steady-state bulk fluorescence measurements using a plate reader. Measurements correlated with the laboratory optical modulation biosensing system (R2 = 0.98). In an anti-dengue virus serotype 2 (DENV-2) nonstructural protein 1 (NS1) immunoglobulin G (IgG) immunoassay, Chip-OMB achieved a 3 ng/mL limit of detection with a ~4-log dynamic range. Among 56 sera, 29 DENV-2 cases confirmed by reverse transcription quantitative polymerase chain reaction (RT-qPCR) were Panbio IgG-positive and above the exploratory Chip-OMB cutoff, while all 27 study-defined negative controls were below it.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Unlocking Zeptomolar Single-Molecule Detection by Synergizing Digital Microfluidics and Digital CRISPRJournal of the American Chemical Society · 2025
- Microfluidic diffusional sizing in bioanalysis and biosensing.Lab on a chip · 2026
- Label-free biomolecular sensing via near-interface single-particle Brownian motion tracking.Biosensors & bioelectronics · 2026
- Microbead-Based Heterodimer Assay for Amplification-Free Detection of Single-Stranded DNAbioRxiv · 2026
- Single-Excitation, Orthogonally Encoded Quantum Dot Probes for Dual-Mode Multiplexed Biosensing.ACS omega · 2026
- Barcode-Based SlipChip for High-Multiplexed and Trace Sample Digital Quantification with Femtomolar SensitivityACS Sensors · 2025