Biosensors

Physics-Guided Neural Phase Demodulation for Non-Contact Laser-Ultrasound Sensing of Corneal Phantom Deformation.

Muhammad Awais, Younggue Kim, Byeong Ha Lee

Department of Electrical Engineering and Computer Science, Gwangju Institute of Science and Technology, Gwangju 61005, Republic of Korea. · Korea Photonics Technology Institute, Gwangju 61007, Republic of Korea.

Key points

From the paper's conclusion
  • These results demonstrate a fast physics-guided optical detection framework for non-contact sensing of weak acoustic responses, supporting the use of 3 × 3 optical interferometry as a biosensing approach for LUS and photoacoustic applications.

Abstract

Non-contact detection of weak, transient acoustic signals is essential for photoacoustic and laser-ultrasound (LUS) bioimaging, including the assessment of corneal deformation and thickness variation. Passive 3 × 3 fiber-coupler interferometers provide phase-diverse sensing without external modulation; however, conventional ellipse-based calibration becomes unreliable when the measured phase excursion covers only a small fraction of the characteristic ellipse, as in nanometer-scale corneal responses. This study presents a physics-guided temporal convolutional network (PG-TCN) that directly maps two nonideal interferometric outputs to a continuous dynamic phase signal without ellipse fitting or separate phase unwrapping during inference. The model combines dilated one-dimensional convolutions with interferometric-consistency and temporal-regularization losses. Tests using PZT-modulated calibration signals acquired under several static chamber pressures of 10, 15, 20, and 25 kPa showed lower mean absolute error, higher normalized cross-correlation, and lower displacement RMSE than a CNN-LSTM baseline. In corneal-phantom LUS measurements, the first detected echo shifted from 4.632 to 4.488 µs between 10 and 20 kPa, corresponding to a relative thickness reduction of approximately 7.8 µm/kPa. The PG-TCN required 210 ± 18 µs per sequence while using approximately half the trainable parameters of the CNN-LSTM baseline. These results demonstrate a fast physics-guided optical detection framework for non-contact sensing of weak acoustic responses, supporting the use of 3 × 3 optical interferometry as a biosensing approach for LUS and photoacoustic applications.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Physics-Guided Neural Phase Demodulation for Non-Contact Laser-Ultrasound Sensing of Corneal Phantom Deformation — Science Skim