Physics-Guided Neural Phase Demodulation for Non-Contact Laser-Ultrasound Sensing of Corneal Phantom Deformation.
Muhammad Awais, Younggue Kim, Byeong Ha Lee
Department of Electrical Engineering and Computer Science, Gwangju Institute of Science and Technology, Gwangju 61005, Republic of Korea. · Korea Photonics Technology Institute, Gwangju 61007, Republic of Korea.
Key points
From the paper's conclusion- These results demonstrate a fast physics-guided optical detection framework for non-contact sensing of weak acoustic responses, supporting the use of 3 × 3 optical interferometry as a biosensing approach for LUS and photoacoustic applications.
Abstract
Non-contact detection of weak, transient acoustic signals is essential for photoacoustic and laser-ultrasound (LUS) bioimaging, including the assessment of corneal deformation and thickness variation. Passive 3 × 3 fiber-coupler interferometers provide phase-diverse sensing without external modulation; however, conventional ellipse-based calibration becomes unreliable when the measured phase excursion covers only a small fraction of the characteristic ellipse, as in nanometer-scale corneal responses. This study presents a physics-guided temporal convolutional network (PG-TCN) that directly maps two nonideal interferometric outputs to a continuous dynamic phase signal without ellipse fitting or separate phase unwrapping during inference. The model combines dilated one-dimensional convolutions with interferometric-consistency and temporal-regularization losses. Tests using PZT-modulated calibration signals acquired under several static chamber pressures of 10, 15, 20, and 25 kPa showed lower mean absolute error, higher normalized cross-correlation, and lower displacement RMSE than a CNN-LSTM baseline. In corneal-phantom LUS measurements, the first detected echo shifted from 4.632 to 4.488 µs between 10 and 20 kPa, corresponding to a relative thickness reduction of approximately 7.8 µm/kPa. The PG-TCN required 210 ± 18 µs per sequence while using approximately half the trainable parameters of the CNN-LSTM baseline. These results demonstrate a fast physics-guided optical detection framework for non-contact sensing of weak acoustic responses, supporting the use of 3 × 3 optical interferometry as a biosensing approach for LUS and photoacoustic applications.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Physics-guided neural reconstruction of corneal topography from Placido-ring images.Journal of the Optical Society of America. A, Optics, image science, and vision · 2026
- Physics-based multibranch hybrid deep learning-assisted resonance method for rapid and high-precision measurement of optical resonator loss.Optics letters · 2026
- Contact lens with stretchable distributed-feedback laser for intraocular pressure monitoringarXiv · 2026
- Physics-informed deep learning for phase retrieval and self-calibration in Zernike phase-contrast microscopy.Optics letters · 2026
- Neural aberration fields: continuous implicit representation of spatially varying point spread functions for vision simulation.Journal of the Optical Society of America. A, Optics, image science, and vision · 2026
- Deep Learning Enabled Ultrafast Optical Spectral Phase Retrieval via Unbalanced-Intensity Autocorrelation.Nanophotonics (Berlin, Germany) · 2026