Flow-Stabilized Microfluidic Sensing of Thermally Induced Changes in Red Blood Cell Aggregation During Closed-Loop Circulation.
Yang Jun Kang
Department of Mechanical Engineering, Chosun University, 10, Chosundae 1-gil, Dong-gu, Gwangju 61452, Republic of Korea.
Key points
From the paper's conclusion- These results demonstrate continuous detection of thermally induced changes in RBC aggregation at a fixed measurement temperature of 25 °C without interrupting circulation and provide a versatile framework for investigating progressive changes in aggregation behavior under controlled and reproducible in vitro conditions.
Abstract
Red blood cell (RBC) aggregation is a sensitive indicator of hemorheological alterations, but conventional methods generally rely on intermittent or end-point measurements. This study presents a flow-stabilized closed-loop microfluidic platform for continuous measurement of the RBC aggregation index (AI) during controlled circulation and thermal exposure. The system integrates a peristaltic pump, hydraulic flow stabilizer (FS), microfluidic aggregation sensor, and thermal mixer to suppress flow pulsation and RBC sedimentation. The FS increases the characteristic flow-response time by approximately 17.6-fold, markedly attenuating pump-induced fluctuations. Under stabilized conditions, flow rates in the main channel and test chamber remain highly linear with the imposed flow rate, while stable AI measurements are maintained for at least 30 min. The platform also resolves dextran-dependent changes in RBC aggregation during continuous circulation. During thermal exposure from 25 to 47 °C, main-channel image intensity (Imc) and AI remain nearly constant up to 43 °C, whereas exposure at ≥45 °C causes a progressive increase in Imc and a marked decrease in AI. These results demonstrate continuous detection of thermally induced changes in RBC aggregation at a fixed measurement temperature of 25 °C without interrupting circulation and provide a versatile framework for investigating progressive changes in aggregation behavior under controlled and reproducible in vitro conditions.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Continuous Measurement of Spatially Resolved Red Blood Cell Aggregation Using Multiple Side-Branch Channels.Biosensors · 2026
- Microfluidic Chip Platforms for Red Blood Cell Storage Lesion Quality Control and Precision Transfusion.Research (Washington, D.C.) · 2026
- Laser-optic techniques for assessing blood microrheology in health and disease.Biophysical reviews · 2026
- PolyJet 3D-printed microfluidic device that integrates hydrodynamic focusing of red blood cells and detection of ATP release.Analytical methods : advancing methods and applications · 2026
- Rapid Electrochemical Impedance Detection of the Mia Antigen on Red Blood Cells.ACS omega · 2026
- Neuraminidase-Mediated Desialylation Modulates Red Blood Cell Aggregation.Biophysical journal · 2026