Key points
From the paper's conclusion- These results demonstrate the feasibility of the SPCE/GO-cysteamine platform for Cd(II) determination in digested fruit matrices and support its further development as a portable screening approach for food-quality control.
Abstract
Cadmium contamination in fruits is a relevant food-safety concern because of its toxicity, environmental persistence, and potential transfer from agricultural soils to edible plant tissues. This study developed a screen-printed carbon electrode modified with graphene oxide and cysteamine (SPCE/GO-cysteamine) to determine Cd(II) by square-wave anodic stripping voltammetry (SWASV). Two surface-modification routes, GO-cysteamine and GO-rGO-cysteamine, and GO concentrations of 0.1, 0.2, and 0.5 mg mL-1 were compared by cyclic voltammetry. The direct GO-cysteamine route at 0.2 mg mL-1 produced the highest CV response among the tested conditions and was selected for Cd(II) determination. Raman spectroscopy FTIR spectroscopy and scanning electron microscopy were used to characterize the graphene-based materials employed during surface optimization. Cd(II) concentrations from 1 to 10 µg L-1 were experimentally evaluated; with a calculated LOQ of 0.74 µg L-1, the entire experimentally evaluated range of 1-10 µg L-1, with a sensitivity of 11.30 µA (µg L-1)-1, R2 = 0.9892, a limit of detection of 0.25 µg L-1 and a limit of quantification of 0.74 µg L-1. Fortified Kent mango and Hass avocado digestates also showed concentration-dependent responses, with R2 values of 0.9799 and 0.9788, respectively, and relative standard deviations below 5%. These results demonstrate the feasibility of the SPCE/GO-cysteamine platform for Cd(II) determination in digested fruit matrices and support its further development as a portable screening approach for food-quality control.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Detection of Cd2+ and Pb2+ in egg yolk and maize samples by a novel SDA/MWCNTs-based electrochemical sensor.RSC advances · 2026
- Green synthesis of graphene oxide–citric acid (GOCC) nanocomposite for Cd (II) and Pb (II) adsorption: adsorption studies and BBD-RSM modellingCanadian Metallurgical Quarterly · 2026
- Site-Directed Functionalization of MXene/GO with Cysteine for Dual-Metal Ion Detection: A Plug-and-Play Paper ElectrodesACS Applied Nano Materials · 2026
- Development of an eco-friendly sensor manufactured from reused milk cartons and graphene-based conductive ink as substrates.Analytical methods : advancing methods and applications · 2026
- Magnetic-assisted electrochemical detection of Pb²⁺ and Cd²⁺ in Vietnamese seafood using Fe₃ O₄ @UiO-66-Py/rGONanoscale · 2026
- Chitosan-lipoic acid conjugate as an adsorbent for dispersive solid-phase microextraction of Cd, Cu and Pb in infant formulasScientific Reports · 2026