Melanin Bias in Cerebral fNIRS: A Monte Carlo Study Toward Equitable Optical Brain Sensing.
Murad Althobaiti
Department of Biomedical Engineering, College of Engineering, Imam Abdulrahman Bin Faisal University, P.O. Box 1982, Dammam 31441, Saudi Arabia.
Key points
From the paper's conclusion- Because epidermal melanin is a strong near-infrared absorber, device sensitivity may depend on skin tone, raising an equity concern for optical neural biosensors. (1) Objective: We quantify, by Monte Carlo simulation, how epidermal melanin biases the cerebral sensitivity of continuous-wave fNIRS biosensors across the Fitzpatrick scale, and evaluate source-wavelength selection as a device-level mit
Abstract
Functional near-infrared spectroscopy (fNIRS) is an optical biosensing modality that transduces cortical hemodynamics into a measurable near-infrared signal, underpinning wearable brain monitors and brain-computer interfaces (BCIs). Because epidermal melanin is a strong near-infrared absorber, device sensitivity may depend on skin tone, raising an equity concern for optical neural biosensors. (1) Objective: We quantify, by Monte Carlo simulation, how epidermal melanin biases the cerebral sensitivity of continuous-wave fNIRS biosensors across the Fitzpatrick scale, and evaluate source-wavelength selection as a device-level mitigation. (2) Methods: Using a physically sourced melanin model and a two-stage design-an idealized layered slab for controlled sweeps and the Colin27 anatomical atlas for realistic-geometry confirmation-we computed gray-matter sensitivity for three skin tones, four wavelengths, and seven source-detector separations. (3) Results: Melanin acts as a surface gate that lowers absolute cerebral sensitivity by up to ~12.5-fold (at 690 nm) for dark skin-and by ~5-fold at the 850 nm optimum-while preserving depth selectivity; longer wavelengths reduce the penalty (dark-skin retained sensitivity rising from 8.0% at 690 nm to 29.6% at 940 nm) but never remove it; and 850 nm is a practical optimum for single-wavelength cerebral sensitivity, combining the highest absolute sensitivity with improved equity, whereas 940 nm gains relative equity only as absolute signal collapses through water absorption. Atlas simulations reproduce the 850 nm optimum in realistic anatomy under identical optical assumptions and show that idealized slabs overestimate sensitivity ~50-fold and that sensitivity varies ~19-fold with probe placement. (4) Conclusions: Skin tone and anatomy compound to disadvantage darker-skinned users of optical neural biosensors; wavelength selection and a sourced correction-factor framework offer concrete routes toward equitable device design.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Skin tone and diagnostic equity in contactless blood pressure screening: a prospective observational field evaluation of remote photoplethysmography in NigeriaBMJ Open · 2026
- Anatomical and spectral foundation of skin pigmentation bias in optical oximetrymedRxiv · 2026
- Developing Best Practices for Inclusion in fNIRS Research: Equity for Participants With Afro‐Textured HairDevelopmental Psychobiology · 2026
- Next-Generation Wearable fNIRS: A Comprehensive Review of Bio-Instrumentation and Hardware ArchitecturesApplied Sciences · 2026
- MtReNIRS: A Self-Supervised Foundation Model for Transferable Neurovascular RepresentationsarXiv · 2026
- Wireless, optoelectronic, multimodal skin sensor for simultaneous monitoring of mechanical stress and vascular responses.Nature communications · 2026