The Evolution of Next-Generation Glucose Monitoring Systems: Developments from Conventional Diagnostics to Wearable and Continuous Sensing Platforms-A Narrative Review.
Sumedha Nitin Prabhu
Biomedical Science & Engineering Programme, School of Medicine, The Chinese University of Hong Kong, Shenzhen 518172, China.
Key points
From the paper's conclusion- Glucose monitoring is crucial for diabetes diagnosis, glycemic control, treatment modification, and avoiding acute and long-term consequences.
- Glucose-monitoring systems have evolved from traditional diagnostic tests and finger-prick electrochemical glucometers to wearable, continuous, minimally invasive, and non-invasive sensing platforms.
- Major barriers include sensitivity, selectivity, calibration, biofouling, biocompatibility, physiological variability, and clinical translation, while opportunities include intelligent, painless, and patient-centered glucose monitoring.
Abstract
For the diagnosis of diabetes, glycemic control, treatment modification, and the avoidance of both acute and long-term consequences, accurate glucose monitoring is crucial. This study examines the development of glucose-monitoring systems, from traditional diagnostic tests and finger-prick electrochemical glucometers to wearable, continuous, minimally invasive, and non-invasive sensing platforms. Major invasive technologies, including enzymatic and non-enzymatic electrochemical sensors, microdialysis systems, hexokinase-based photometric assays, and field-effect transistor biosensors, are critically evaluated. The ability of minimally invasive methods to access interstitial fluid with less pain is discussed, including fluorescence probes, surface-enhanced Raman spectroscopy, and microneedle arrays. Emerging non-invasive approaches are also evaluated. These include reverse iontophoresis, optical coherence tomography, infrared and photoacoustic spectroscopy, microwave resonators, smart contact lenses, and AI-assisted wearable systems. Finally, the review identifies major barriers related to sensitivity, selectivity, calibration, biofouling, biocompatibility, physiological variability, and clinical translation. It also outlines opportunities for intelligent, painless, and patient-centered glucose monitoring.
Read the paper
Discussion · 1
Science Skim's AI key points, plus readers' public thoughts
- Glucose monitoring is crucial for diabetes diagnosis, glycemic control, treatment modification, and avoiding acute and long-term consequences.
- Glucose-monitoring systems have evolved from traditional diagnostic tests and finger-prick electrochemical glucometers to wearable, continuous, minimally invasive, and non-invasive sensing platforms.
- Major barriers include sensitivity, selectivity, calibration, biofouling, biocompatibility, physiological variability, and clinical translation, while opportunities include intelligent, painless, and patient-centered glucose monitoring.
Readers' thoughts
No reader thoughts yet.
Related papers
- Non-Invasive Technologies in Wearable Glucose Monitoring: A Structured Overview for the Future.Biosensors · 2026
- Microneedle Based Platforms for Glucose Monitoring: Current Status and Future DirectionsBiotechnology and Bioengineering · 2026
- Microneedle-Based Optical Biosensors for Point-of-Care Glucose Monitoring in Interstitial Fluid: Recent Advances, Current Challenges, and Future Perspectives.Biosensors · 2026
- Non-Invasive Blood Glucose Monitoring Using Machine Learning and Optical Approaches: A Systematic Literature Review and a Proposed Framework for Reproducible and Clinically Reliable Research.Sensors (Basel, Switzerland) · 2026
- Continuous glucose monitoring (CGM) systems in Poland, Europe, and beyond in 2025: principles, available technologies, and future perspectives.Archives of medical science : AMS · 2026
- Clinical validation of noninvasive blood glucose measurements by midinfrared spectroscopyCommunications Medicine · 2025