Deep Learning-Assisted Accuracy Improvement in Bladder Cancer Staging of Spectrum-Aided Visual Enhanced Cystoscopy Images.
Kuan-Hsun Huang, Yu-You Liu, Chia-Chien Wu, Chia-Ling Chen, Jie-Lun Hsieh, Lung-Hsiang Chuo, Hsiang-Chen Wang
Department of Urology, Dalin Tzu Chi Hospital, Buddhist Tzu Chi Medical Foundation, No. 2, Minsheng Road, Dalin, Chiayi 62247, Taiwan. · Graduate Institute of Opto-Mechatronics, Department of Mechanical Engineering, National Chung Cheng University, 168, University Rd., Min Hsiung, Chiayi 62102, Taiwan.
Key points
From the paper's conclusion- The results demonstrate that combining algorithmic hyperspectral reconstruction with deep learning architectures effectively addresses the challenges of clinical data interpretation and significantly enhances the detection and staging performance of bladder cancer imaging.
Abstract
Recent statistics reported by the World Health Organization and the International Agency for Research on Cancer indicate that the global incidence of bladder cancer has continued to increase in recent years, particularly in industrialized countries. Therefore, the timely diagnosis of early-stage bladder cancer is of great clinical importance for improving patient prognosis and treatment outcomes. In this context, computational optical sensing frameworks that integrate Spectrum-Aided Visual Enhancer (SAVE) technology with cystoscopy have attracted significant attention to overcome the limitations of conventional visual data interpretation. In this study, an AI-driven optical biosensing framework was evaluated using 1372 white-light cystoscopy (WLC) images of bladder cancer (RGB-WLC) collected in collaboration with Chung Shan Medical University Hospital. Hyperspectral conversion technology was applied to extract precise spectral information from the white-light images. Subsequently, dimensionality reduction was performed based on the characteristic wavelengths of narrow-band imaging cystoscopy at 415 nm and 540 nm to generate hyperspectral reconstructed narrow-band images. The images were categorized into Ta stage (Ta), above T1 stage (Above T1), and four additional classes. The dataset was divided into training and testing sets to establish both a standard white-light cystoscopy model (RGB-WLC) and an advanced hyperspectral biosensing model utilizing the YOLOv8 architecture for enhanced pattern recognition. Model performance was evaluated using sensitivity, F1-score, and overall accuracy. The standard RGB-WLC model achieved an accuracy of 0.852, whereas the SAVE-based biosensing model achieved an accuracy of 0.948, representing an improvement of approximately 11.27%. The results demonstrate that combining algorithmic hyperspectral reconstruction with deep learning architectures effectively addresses the challenges of clinical data interpretation and significantly enhances the detection and staging performance of bladder cancer imaging.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Optical Spectroscopy and Spectral Imaging for Bladder Cancer Detection and Characterisation: A Scoping Review of Diagnostic Evidence and Translational Readiness.Diagnostics (Basel, Switzerland) · 2026
- Transforming Endoscopic Image Classification with Spectrum-Aided Vision for Early and Accurate Cancer IdentificationDiagnostics · 2025
- Study of bladder cancer detection in standard white light versus AI-supported endoscopy-01 (RAISE-01) – Development and validation of an AI-based support toolInternational Journal of Medical Informatics · 2026
- Efficacy of Spectral-Aided Visual Enhancer in Classification of Esophageal CancerCancers · 2026
- Serum Raman spectroscopy as a blood-based triage test for bladder cancer: a retrospective proof-of-concept studymedRxiv · 2026
- AI-Driven Hyperspectral Imaging in Clinical Medicine: A Critical Appraisal of Translational Readiness.Diagnostics (Basel, Switzerland) · 2026