Key points
From the paper's conclusion- This excellent analytical performance was attributed to the stable Pyr-NHS functionalisation, the 3D graphene foam enabling superior conductivity and a larger surface area on the working electrode, and the optimisation of antibody concentration for immobilisation.
Abstract
Alzheimer's Disease (AD) is one of the most commonly seen neurodegenerative disorders, where early detection of its biomarkers is crucial for effective management. Conventional diagnostic methods are often expensive, time-consuming, and highly complex, which highlights an urgent need for point-of-care biosensing technology. In this work, we developed assays on three-dimensional (3D) graphene foam electrodes by functionalising them with a 1-Pyrenebutyric acid N-hydroxysuccinimide ester (Pyr-NHS) to enable effective antibody immobilisation for the detection of amyloid beta peptides (Aβ42 and Aβ40), key biomarkers for AD. Pyr-NHS linkers were used for stable functionalisation, followed by binding with Aβ42 and Aβ40 antibodies, and then bovine serum albumin (BSA) was employed as a blocking agent to minimise non-specific bindings on the electrode surface. Differential Pulse Voltammetry (DPV) measurements showed satisfactory stability over 12 days (RDS upper limit was <10%) and highly sensitive and specific detection of Aβ42 and Aβ40, with insignificant interference of tau217 protein. The biosensor exhibited a low limit of detection (LOD) with 252 aM for Aβ42 and 395 aM for Aβ40, covering 0.125 fM-1 nM and 0.125 fM-100 pM linear ranges, respectively. Further validation was conducted on spiked-diluted human plasma. This excellent analytical performance was attributed to the stable Pyr-NHS functionalisation, the 3D graphene foam enabling superior conductivity and a larger surface area on the working electrode, and the optimisation of antibody concentration for immobilisation. These promising results suggest that 3D graphene foam-based biosensors have considerable potential for early detection of AD biomarkers and developing cost-effective, portable, and reliable point-of-care devices.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Sensitive detection of amyloid-β42 using a graphitic carbon nitride-boosted electrochemical peptide biosensor.Mikrochimica acta · 2026
- A Robust Biosensor Based on the Pd−S Bond-Immobilized Peptide toward Antifouling Electrochemical Detection of an Alzheimer’s Disease Biomarker in SerumACS Sensors · 2026
- Highly sensitive and specific high-throughput detection of Aβ42 in clinical specimens using a G-quadruplex-structured fluorescent aptamer analysis platform.Talanta · 2026
- Revealing Aβ peptide isoforms, including post-translationally modified species, through Cu(II)-mediated electrochemical profiling using a dual-electrode set-up.Talanta · 2026
- A signal-locked clamped hybridization chain reaction nanoamplifier for rapid and highly sensitive analysis of Aβ42.Talanta · 2026
- C-Terminal Epitope-Imprinted Polymer-Coated Electrodes for Selective Sensing of β-Amyloid Peptide 42.Biosensors · 2026