Design and Simulation of Indoor Humidity Regulation Using a Biomimetic Building Window Inspired by the Pine Cone Scale Structure
Pan Pei, Yihan Wang, Haoyu Xie, Yifei Sun, Yuxuan Peng, Zhenjun Yu, Yangyang Wei
Key points
From the paper's conclusion- Across three 12 h humidity scenarios (moderate, high-humidity, and extreme abrupt-change), the biomimetic window limited indoor RH amplitudes at the room center to 5.6%, 4.8%, and 27.0%, respectively, compared with 23.1%, 27.9%, and 45.5% for the conventional window and 13.0%, 24.8%, and 44.9% for the fixed-throttle window.
Abstract
Indoor environments in hot–humid climates often rely on energy-intensive active dehumidification, while conventional smart windows primarily regulate light and heat, with limited attention to humidity control. Inspired by the humidity-responsive movement of pine cone scales, this study proposes a passive biomimetic window and evaluates its building-scale performance through transient computational fluid dynamics (CFD) simulations. Under the subtropical monsoon climate of Nanchang, China, a benchmark residential model was established, with window opening controlled by a prescribed dynamic boundary based on external relative humidity changes (ΔRH) and a one-way diffusion–bending model. Coupled airflow, temperature, and water vapor transport were simulated, comparing the biomimetic window with conventional and fixed-throttle windows having the same time-averaged opening ratio. Across three 12 h humidity scenarios (moderate, high-humidity, and extreme abrupt-change), the biomimetic window limited indoor RH amplitudes at the room center to 5.6%, 4.8%, and 27.0%, respectively, compared with 23.1%, 27.9%, and 45.5% for the conventional window and 13.0%, 24.8%, and 44.9% for the fixed-throttle window. This indicates its potential to buffer external moisture fluctuations and mitigate the sudden moisture shock load imposed on active systems. Under a 180 s high-humidity shock, the biomimetic window improved indoor airflow distribution and reduced stagnation zones, decreasing horizontal and vertical temperature differences from 2.3 °C to 0.8 °C and from 3.1 °C to 1.2 °C, respectively. Indoor RH fluctuations remained within 12%, and dew point temperature differences among monitoring points remained within 1.5 °C, indicating a more coordinated humidity response. By translating the hygroscopic bilayer principle of pine cone scales into a perforated-plate humidity gate, this study evaluates its room-scale airflow, thermal, and moisture responses, providing a reference for developing passive, low-energy-oriented humidity-responsive windows.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Comparative Energy and Thermal Performance of Biomimetic Louver Retrofits in Hot-Arid Climate Residential Buildings.Biomimetics (Basel, Switzerland) · 2026
- Stomata-Inspired Composite Films for All-Climate Dynamic Thermal Management in High-Humidity Environments.ACS applied materials & interfaces · 2026
- From Biomimicry to Climate-Responsive Architecture: Prioritizing Bio-Based and Bio-Inspired Strategies for Sustainable Buildings in Tropical Monsoon ClimatesBuildings · 2026
- Indoor temperature and humidity prediction in residential buildings: A review of the white box and black box modeling techniquesBuilding and Environment · 2025
- Quantifying the Energy Performance of Biomimetic Façade Systems in Hot–Arid Residential Buildings: A Libyan Case StudyBuildings · 2026
- Flexible Hygroscopic Electronics for Real‐Time Moisture Sorption‐Desorption Monitoring and Smart Humidity RegulationAdvanced Materials · 2026