Homeostasis-Inspired, Quality-Adaptive Preprocessing for Multi-Label ECG Diagnosis: A Pre-Registered Multi-Objective Evolutionary Study with Negative Findings and Falsifiable Design Principles.
Hüseyin Yanık
Department of Information Systems and Technologies, Mersin University, 33343 Mersin, Türkiye.
Key points
From the paper's conclusion- Post hoc analyses explain these negative results: the operator bank offered no tier-dependent trade-off, the worst-tier objective was rarely binding, the sensor saturated because its tier boundaries were fitted on clean data, the sensor cost exceeded the filtering it saved, and the selected operators were unstable across resamples, while the qualitative rule “filter only the disturbed tier” was st
Abstract
Deep-learning electrocardiogram (ECG) classifiers usually apply one fixed preprocessing filter to every recording, although signal quality varies. Inspired by physiological homeostasis, ECG preprocessing was formulated as a sensor-controller-effector loop: a weakly supervised quality sensor assigns each 12-lead record to a quality tier, and a tier-gated policy, shaped by Non-dominated Sorting Genetic Algorithm II (NSGA-II) on the validation fold, selects a filtering operator and a calibration temperature for a frozen compact Convolutional Neural Networks (CNN). In a pre-registered evaluation on PTB-XL v1.0.3 (21,388 records), the adaptive policy did not outperform the best fixed band-pass filter in discrimination (test macro area under the receiver operating characteristic curve (AUROC 0.9225 vs. 0.9231), worst-tier performance, or calibration, on native data or on any of 15 synthetic and real (MIT-BIH Noise Stress Test) noise benches. Like the fixed filter, it clearly outperformed unfiltered processing under baseline wander (ΔAUROC +0.0047, Holm-adjusted p < 0.001). Post hoc analyses explain these negative results: the operator bank offered no tier-dependent trade-off, the worst-tier objective was rarely binding, the sensor saturated because its tier boundaries were fitted on clean data, the sensor cost exceeded the filtering it saved, and the selected operators were unstable across resamples, while the qualitative rule "filter only the disturbed tier" was stable. Of four predictions derived from homeostasis, one was supported, two were supported only partially, and one was refuted. This study distills six falsifiable design principles for bio-inspired adaptive signal processing.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- RhythmX™: An Interpretable Self-Supervised Contrastive Learning Framework for Heartbeat ClassificationTechnologies · 2026
- Evaluator-Dependent Patient-Adaptive ECG Lead-Channel AllocationarXiv · 2026
- Deep learning for ECG-based cardiovascular diagnosis: a review of model architecturesEvolutionary Intelligence · 2026
- XAI-ECGNet: an explainable hybrid CNN-BiLSTM framework for multi-label cardiac diagnosis classification from 12-lead ECG signals using the PTB-XL datasetScientific Reports · 2026
- Deep learning–based ECG analysis for predicting heart failure with improved ejection fraction: a multimodal late fusion studyFrontiers in Medicine · 2026
- Foundation models for electrocardiogram interpretation: clinical implicationsEuropean Heart Journal · 2025