Force-Vision Multimodal Measurement of Model-Equivalent Elastic Parameters for Soft Tissue Modeling.

Le Zhang, Yi Liu, Ziyu Liang, Dapeng Yang

State Key Laboratory of Robotics and Systems, Harbin Institute of Technology, Harbin 150080, China.

Key points

From the paper's conclusion
  • The proposed framework provides an approach for rapid parameter identification of deformable-tissue contact models, with potential to support more consistent reproduction of contact force and deformation in soft-tissue simulation and future sim2real robotic manipulation with force-vision feedback.

Abstract

In robotic manipulation, robot-assisted surgery, and other contact-rich interactions with deformable bodies, reliable prediction of contact force and deformation requires rapid determination of the effective mechanical parameters governing the soft-tissue model. However, these model-equivalent properties are difficult to obtain directly from physical interaction, particularly for human soft tissue with substantial variability in geometry and mechanical response. This work presents a force-vision multimodal framework for rapidly identifying effective elastic and contact-model parameters from measured force and deformation. The human breast is selected as a representative validation object because of its high compliance, pronounced geometric variability, and sensitivity of its deformation response to mechanical properties and contact conditions. A six-axis force/torque sensor and an eye-in-hand RGB-D camera provide time-synchronized measurements of three-dimensional contact force and surface-marker displacement. A finite-element contact model maps the probe pose and a parameter vector to the measured responses, while a multiobjective Bayesian optimization procedure identifies the parameter set under a limited simulation budget. Experiments using three breast-tissue-mimicking phantoms with different geometries and stiffnesses yield normalized force and displacement residuals of 4.93%-6.00% and 7.18%-12.33%, respectively, within 55 model evaluations. Force and displacement provide complementary constraints, and the Bayesian solver achieves residuals comparable to particle swarm optimization with a 5.5-fold reduction in the number of finite-element evaluations. Held-out indentation and controlled posture-change tests further support the predictive consistency of the identified model-equivalent parameters within the experimental protocol. The proposed framework provides an approach for rapid parameter identification of deformable-tissue contact models, with potential to support more consistent reproduction of contact force and deformation in soft-tissue simulation and future sim2real robotic manipulation with force-vision feedback.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Force-Vision Multimodal Measurement of Model-Equivalent Elastic Parameters for Soft Tissue Modeling — Science Skim