Bioinspired Injectable Thermosensitive Gallic Acid-Conjugated Hyaluronic Acid/Pluronic Hydrogels to Prevent Postoperative Adhesion.
Jeong Yun Lee, Hyun Ho Shin, Seongyeon Jo, Da Han Hyun, Ji Hyun Ryu
Department of Biomedical Materials Science, Graduate School of JABA, Wonkwang University, Iksan 54538, Jeonbuk, Republic of Korea. · R&D Center, SCL Science Inc., Seoul 07282, Republic of Korea.
Key points
From the paper's conclusion- Therefore, HA-GA/PluF hydrogels provide reversible thermosensitive properties with enhanced stability and retention, supporting their potential as injectable physical barriers for postoperative adhesion prevention.
Abstract
Postsurgical adhesions are common complications of abdominal and pelvic surgeries, often leading to bowel obstruction, chronic pain, and increased risks during reoperation. Although various physical barrier materials have been developed to prevent postsurgical adhesions, retaining anti-adhesive materials at surgical sites is challenging. In this study, we developed thermosensitive injectable gallic acid-conjugated hyaluronic acid (HA-GA) and Pluronic F127 (PluF) composite hydrogels to retain anti-adhesive materials and prevent postsurgical adhesion. The incorporation of HA-GA reduced the critical gelation concentration of PluF from approximately 18 to 12 wt% and decreased the gelation temperature from 28.5 °C for PluF to 25.6 °C for HA-GA (2 wt%)/PluF hydrogels with the left-shift in sol-gel curves. The G' values increased from 10.1 ± 1.7 kPa for PluF to 24.8 ± 3.6 kPa for HA-GA (2 wt%)/PluF hydrogels at 37 °C. In addition, the HA-GA/PluF hydrogels exhibited enhanced mass retention as a function of time compared to PluF hydrogels alone. HA-GA (2 wt%)/PluF hydrogels retained 33.4 ± 3.5% of their initial mass after 7 d, whereas PluF was completely eroded within 3 d. The anti-adhesion efficacy of the HA-GA/PluF hydrogels was evaluated using a rat cecum abrasion model. Notably, the HA-GA (2 wt%)/PluF hydrogels showed reduced adhesion scores, with an adhesion extent score of 0.67 and 2.33 on postoperative day 7 and 21, respectively, compared with the untreated control group (3 and 3 on postoperative day 7 and 21). In addition, the adhesion severity scores of HA-GA (2 wt%)/PluF hydrogel groups were 0.33 and 1.33 on postoperative day 7 and 21, respectively, compared with the untreated control groups (1.67 and 2.33 on postoperative day 7 and 21). Therefore, HA-GA/PluF hydrogels provide reversible thermosensitive properties with enhanced stability and retention, supporting their potential as injectable physical barriers for postoperative adhesion prevention.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Anti-Adhesion Effects and Potential Mechanisms of Polyglutamic Acid-Polylysine Crosslinked Hydrogels in a Rat Peritoneal Adhesion Model.Gels (Basel, Switzerland) · 2026
- A Multifunctional, In Situ Fast‐Gelling Polyurethane‐Graft‐Chitooligosaccharide Hydrogel for Postoperative Adhesion TherapyJournal of Applied Polymer Science · 2026
- An Injectable Hydrogel Enabling Photo‐Temporal Modulation of Asymmetric Adhesion for Tissue Fixation and Prevention of Postoperative Peritoneal AdhesionAdvanced Functional Materials · 2025
- Development of an anti-adhesive gelatin film-cut: A preliminary study of biological properties.Journal of bioscience and bioengineering · 2026
- A self-healing pH-responsive injectable zwitterionic hydrogel for the prevention of postoperative adhesions.Biomaterials advances · 2026
- Application of Photocrosslinkable Wet-Adhesive Composite Hydrogel Adhesive in Bladder Injury Repair.Bioengineering (Basel, Switzerland) · 2026